<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v3.0 20080202//EN" "journalpublishing3.dtd">
<article xml:lang="en" article-type="research-article" xmlns:xlink="http://www.w3.org/1999/xlink">
<?release-delay 0|0?>
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">OL</journal-id>
<journal-title-group>
<journal-title>Oncology Letters</journal-title></journal-title-group>
<issn pub-type="ppub">1792-1074</issn>
<issn pub-type="epub">1792-1082</issn>
<publisher>
<publisher-name>D.A. Spandidos</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3892/ol.2014.2039</article-id>
<article-id pub-id-type="publisher-id">ol-07-06-1987</article-id>
<article-categories>
<subj-group>
<subject>Articles</subject></subj-group></article-categories>
<title-group>
<article-title>Volumetric modulated arc radiotherapy sparing the thyroid gland for early-stage glottic cancer: A dosimetrical analysis</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>KIM</surname><given-names>EUN SEOK</given-names></name></contrib>
<contrib contrib-type="author">
<name><surname>YEO</surname><given-names>SEUNG-GU</given-names></name><xref ref-type="corresp" rid="c1-ol-07-06-1987"/></contrib>
<aff id="af1-ol-07-06-1987">Department of Radiation Oncology, Soonchunhyang University College of Medicine, Cheonan, Chungnam 330-721, Republic of Korea</aff></contrib-group>
<author-notes>
<corresp id="c1-ol-07-06-1987">Correspondence to: Dr Seung-Gu Yeo, Department of Radiation Oncology, Soonchunhyang University College of Medicine, 31 Soonchunhyang 6-gil, Cheonan, Chungnam 330721, Republic of Korea, E-mail: <email>md6630@daum.net</email></corresp></author-notes>
<pub-date pub-type="ppub">
<month>6</month>
<year>2014</year></pub-date>
<pub-date pub-type="epub">
<day>04</day>
<month>04</month>
<year>2014</year></pub-date>
<volume>7</volume>
<issue>6</issue>
<fpage>1987</fpage>
<lpage>1991</lpage>
<history>
<date date-type="received">
<day>09</day>
<month>12</month>
<year>2013</year></date>
<date date-type="accepted">
<day>27</day>
<month>03</month>
<year>2014</year></date></history>
<permissions>
<copyright-statement>Copyright &#x000A9; 2014, Spandidos Publications</copyright-statement>
<copyright-year>2014</copyright-year>
<license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/3.0">
<license-p>This is an open-access article licensed under a Creative Commons Attribution-NonCommercial 3.0 Unported License. The article may be redistributed, reproduced, and reused for non-commercial purposes, provided the original source is properly cited.</license-p></license></permissions>
<abstract>
<p>Previous studies on advanced radiotherapy (RT) techniques for early stage glottic cancer have focused on sparing the carotid artery. However, the aim of the present study was to evaluate the dosimetric advantages of volumetric modulated arc therapy (VMAT) in terms of sparing the thyroid gland in early-stage glottic cancer patients. In total, 15 cT1N0M0 glottic cancer patients treated with definitive RT using VMAT were selected, and for dosimetric comparison, a conventional RT plan comprising opposed-lateral wedged fields was generated for each patient. The carotid artery, thyroid gland and spinal cord were considered organs at risk. The prescription dose was 63 Gy at 2.25 Gy per fraction. For the thyroid gland and carotid artery, all compared parameters were significantly lower with VMAT compared with conventional RT. For the thyroid gland, the median reduction rates of the mean dose (D<sub>mean</sub>), the volume receiving &#x02265;30&#x00025; of the prescription dose (V<sub>30</sub>) and the V<sub>50</sub> were 32.6, 40.9 and 46.0&#x00025;, respectively. The D<sub>mean</sub> was 14.7&#x000B1;2.6 Gy when using VMAT compared with 22.2&#x000B1;3.9 Gy when using conventional RT. The differences between the techniques in terms of planning target volume coverage and dose homogeneity were not significant. When considering a recent normal tissue complication probability model, which indicated the mean thyroid gland dose as the most significant predictor of radiation-induced hypothyroidism, the dosimetric advantage shown in this study may be valuable in reducing hypothyroidism following RT for early stage glottic cancer patients.</p></abstract>
<kwd-group>
<kwd>carotid artery</kwd>
<kwd>early stage</kwd>
<kwd>glottic cancer</kwd>
<kwd>thyroid gland</kwd>
<kwd>volumetric modulated arc therapy</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<title>Introduction</title>
<p>For early-stage (T1-2N0M0) glottic cancer, radiotherapy (RT) and surgery have been demonstrated to yield significant local disease control; &gt;90&#x00025; for T1 and 80&#x00025; for T2. RT is usually the preferred treatment modality, as it has shown a trend towards improved post-treatment functional outcomes, including voice quality, however, a prospective randomized trial has not been performed (<xref rid="b1-ol-07-06-1987" ref-type="bibr">1</xref>).</p>
<p>Such favorable outcomes of RT have been achieved using simple RT techniques of parallel-opposed lateral beams with wedges or tissue compensators (<xref rid="b2-ol-07-06-1987" ref-type="bibr">2</xref>). However, advanced RT techniques, including intensity-modulated RT (IMRT) and volumetric modulated arc therapy (VMAT), have been adopted rapidly for various head and neck cancers. By contrast, RT techniques used for early-stage glottic cancer have not changed considerably, possibly since the target volume is relatively small and involves no elective nodal irradiation, with low rates of severe toxicity (<xref rid="b2-ol-07-06-1987" ref-type="bibr">2</xref>,<xref rid="b3-ol-07-06-1987" ref-type="bibr">3</xref>). One previous study questioned the role of IMRT in early-stage glottic cancer (<xref rid="b4-ol-07-06-1987" ref-type="bibr">4</xref>).</p>
<p>The carotid artery, which is located adjacent to the larynx, is often overlooked, but has recently received attention in several studies that have analyzed the use of advanced RT techniques for patients with early-stage glottic cancer (<xref rid="b5-ol-07-06-1987" ref-type="bibr">5</xref>&#x02013;<xref rid="b10-ol-07-06-1987" ref-type="bibr">10</xref>). RT has emerged as a significant risk factor for carotid artery stenosis and ischemic stroke in head and neck cancer patients (<xref rid="b11-ol-07-06-1987" ref-type="bibr">11</xref>,<xref rid="b12-ol-07-06-1987" ref-type="bibr">12</xref>). The thyroid gland is also located close to the larynx, and hypothyroidism is a late complication frequently observed following RT to the head and neck region (<xref rid="b13-ol-07-06-1987" ref-type="bibr">13</xref>&#x02013;<xref rid="b15-ol-07-06-1987" ref-type="bibr">15</xref>). The lateral beams of conventional RT pass through a cranial portion of the thyroid gland, however, to date, no study has investigated the benefits of advanced RT techniques regarding this organ in early-stage glottic cancer patients.</p>
<p>The aim of the present study was to investigate the dosimetric advantages of VMAT compared with conventional RT, in terms of sparing the thyroid gland in patients with early stage glottic cancer.</p></sec>
<sec sec-type="methods">
<title>Materials and methods</title>
<sec>
<title>Patients</title>
<p>A total of 15 patients with cT1N0M0 squamous cell carcinoma of the larynx treated with definitive RT using VMAT between 2011 and 2012 were selected. The staging workup included direct laryngoscopy, computed tomography (CT) and <sup>18</sup>F-fluorodeoxyglucose positron emission tomography. The clinical stage was determined according to the American Joint Committee on Cancer staging system, 7<sup>th</sup> edition (<xref rid="b16-ol-07-06-1987" ref-type="bibr">16</xref>). All patients were male, with a median age of 66 years (range, 55&#x02013;76 years).</p>
<p>The patients were immobilized in the supine position with a thermoplastic head and neck mask that included the shoulders to ensure reproducibility of treatments. The planning CT scans were performed using a 16-slice CT scanner (Brilliance CT Big Bore; Philips Medical Systems, Cleveland, OH, USA) with a 0.2-cm slice thickness. Intravenous contrast was used in all patients and all RT plans were generated using the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA, USA). Treatment was conducted using a Novalis<sup>&#x000AE;</sup> Tx system (Varian Medical Systems, Palo Alto, CA, USA and BrainLab, Feldkirchen, Germany) and patient set-up was verified prior to treatment; daily by ExacTrac<sup>&#x000AE;</sup> (BrainLab) and weekly by cone-beam CT. Patients provided written informed consent.</p></sec>
<sec>
<title>RT planning</title>
<p>The clinical target volume included the false and true vocal cords, the anterior and posterior commissure, the arytenoids and the subglottic region, extending from the superior thyroid notch to the bottom of the cricoid cartilage. No cervical lymph nodes were included electively. The planning target volume (PTV) was produced by the addition of a 0.5-cm isotropic set-up margin surrounding the clinical target volume. The PTV was truncated within 0.5 cm of the skin surface in the patients without anterior commissure involvement. The surrounding organs at risk (OARs), including the carotid artery, whole thyroid gland and spinal cord, were delineated. The right and left common, internal and external carotid arteries were contoured starting from the sternoclavicular joints and extending upward to the base of the skull.</p>
<p>For the purpose of comparison, a conventional RT plan was retrospectively generated for each patient, using two opposed-lateral wedged fields. The wedge angle was selected to achieve the most homogeneous dose distribution in the PTV, and the block edge margin was uniformly 0.5 cm around the PTV. The collimator of the Novalis<sup>&#x000AE;</sup> Tx system was angled such that the posterior jaw of the lateral fields was parallel to the cervical spine, and two fields were optimally weighted to provide adequate PTV coverage.</p>
<p>For VMAT, the double-arc plan, which has been previously recommended for locally advanced head and neck cancers due to its higher PTV homogeneity, was selected (<xref rid="b17-ol-07-06-1987" ref-type="bibr">17</xref>). The arc length or gantry span of each arc was adjusted to avoid the OARs where possible. The collimator was rotated to 45&#x000B0; or 315&#x000B0; to minimize the contribution of the tongue-and-groove effect during treatment. Optimizations were performed by interactively adapting the objectives and their priorities to ensure lower doses to the OARs and to improve PTV coverage and homogeneity. Following optimization, the dose calculation was performed using the anisotropic analytical algorithm and Eclipse dose volume optimizer (version 8.9.17; Varian Medical Systems, Palo Alto, CA, USA). All conventional and VMAT plans were generated using 6-MV photons and a high-definition multileaf collimator consisting of 120 leaves, which included 64 2.5-mm central and 56 5-mm peripheral leaves. The prescription dose was 63 Gy at 2.25 Gy per fraction and all plans were normalized so that &#x02265;95&#x00025; of the PTV received 100&#x00025; of the prescription dose.</p></sec>
<sec>
<title>Statistical analysis</title>
<p>Dose-volume histograms (DVHs) were created for all treatment plans, and specific dose-volume parameters were compared for the PTV, thyroid gland, carotid artery and spinal cord. For the PTV, the minimum dose (D<sub>min</sub>), maximum dose (D<sub>max</sub>), mean dose (D<sub>mean</sub>) and volume receiving &#x02265;105&#x00025; of the prescription dose (V<sub>105</sub>) were compared to evaluate PTV coverage and dose homogeneity. For the OARs, the following parameters were compared: D<sub>mean</sub>, V<sub>30</sub> and V<sub>50</sub> for the thyroid gland; D<sub>mean</sub>, V<sub>35</sub> and V<sub>50</sub> for the carotid artery; and D<sub>max</sub> for the spinal cord. Comparisons between the dosimetric parameters were performed using the non-parametric Wilcoxon signed-rank test. All statistical tests were two-sided and performed using SPSS software (version 14.0; SPSS, Inc., Chicago, IL, USA). P&lt;0.05 was considered to indicate a statistically significant difference.</p></sec></sec>
<sec sec-type="results">
<title>Results</title>
<p><xref rid="f1-ol-07-06-1987" ref-type="fig">Figs. 1</xref> and <xref rid="f2-ol-07-06-1987" ref-type="fig">2</xref> show the isodose distributions and DVHs, respectively, according to the RT plan, and <xref rid="tI-ol-07-06-1987" ref-type="table">Table I</xref> shows the dose-volume data for the PTV. For the PTV, no differences were identified in the D<sub>min</sub> or D<sub>mean</sub> between VMAT and conventional RT. The median D<sub>min</sub> and D<sub>mean</sub> values were 51.0 Gy (80.9&#x00025; of the prescription dose) and 62.7 Gy (99.5&#x00025; of the prescription dose) in VMAT, respectively, and 52.3 Gy (83.0&#x00025;) and 62.8 Gy (99.7&#x00025;) in conventional RT, respectively. The D<sub>max</sub> of VMAT tended to be higher when compared with the D<sub>max</sub> of the conventional RT (P&#x0003D;0.074), and the median D<sub>max</sub> values were 66.6 Gy (105.7&#x00025;) and 65.7 Gy (104.3&#x00025;) for VMAT and conventional RT, respectively. However, V<sub>105</sub> was not significantly different between the two plans.</p>
<p><xref rid="tII-ol-07-06-1987" ref-type="table">Table II</xref> shows the dose-volume data for the OARs. For the thyroid gland and carotid artery, all compared parameters were significantly lower in VMAT than in conventional RT. In the thyroid gland, the median reduction rates of the D<sub>mean,</sub> V<sub>30</sub> and V<sub>50</sub> using VMAT were 32.6&#x00025; (range, 26.5&#x02013;46.0&#x00025;), 40.9&#x00025; (range, 30.7&#x02013;45.5&#x00025;) and 46.0&#x00025; (range, 38.4&#x02013;67.2&#x00025;), respectively. In the carotid artery, the median reduction rates of the D<sub>mean</sub>, V<sub>35</sub> and V<sub>50</sub> using VMAT were 45.9&#x00025; (range, 37.0&#x02013;50.4&#x00025;), 49.0&#x00025; (range, 45.0&#x02013;52.5&#x00025;) and 92.5&#x00025; (range, 89.1&#x02013;100&#x00025;), respectively.</p>
<p>The measured volume of the entire thyroid gland ranged between 7.4 and 21.9 cm<sup>3</sup> (median, 14.9 cm<sup>3</sup>). A portion of thyroid gland volume, which was encompassed by lateral beams of conventional RT, ranged between 2.5&#x02013;7.6 cm<sup>3</sup> (median, 4.4 cm<sup>3</sup>); on average, it was 32.8&#x00025; (range, 25.2&#x02013;40.9&#x00025;) of the entire thyroid gland volume.</p></sec>
<sec sec-type="discussion">
<title>Discussion</title>
<p>The partial volume effects between the thyroid gland and hypothyroidism were unclear in the study by Emami <italic>et al</italic> (<xref rid="b18-ol-07-06-1987" ref-type="bibr">18</xref>), which was based on a simple consensus of clinical experience or opinions, with little high-quality clinical data. In addition, the Quantitative Analysis of Normal Tissue Effects in the Clinic reports (<xref rid="b19-ol-07-06-1987" ref-type="bibr">19</xref>) did not include data concerning the thyroid gland. Recently, a normal tissue complication probability (NTCP) model of radiation-induced hypothyroidism has been developed based on a prospective multivariate analysis (<xref rid="b20-ol-07-06-1987" ref-type="bibr">20</xref>). The probability of hypothyroidism increases with a higher D<sub>mean</sub> of the thyroid gland (odds ratio, 1.064/Gy) and decreases with a higher thyroid gland volume (odds ratio, 0.826/cm<sup>3</sup>), indicating that the D<sub>mean</sub> must be minimized (<xref rid="b20-ol-07-06-1987" ref-type="bibr">20</xref>). In the present study, VMAT exhibited a median 32.6&#x00025; reduction in the D<sub>mean</sub> of the thyroid gland compared with conventional RT. In addition, the absolute reduction of the D<sub>mean</sub> was a median of 8.0 Gy (range, 4.6&#x02013;11.1 Gy). Therefore, the VMAT used for early-stage glottic cancer patients may reduce the post-RT risk of developing hypothyroidism, when applying this NTCP model.</p>
<p>Hypothyroidism is a late toxicity that frequently occurs following curative RT to the head and neck region. The incidence of subclinical (high serum thyrotropin) and clinical (high serum thyrotropin and thyroxine) hypothyroidism following RT to the head and neck region varies between 23 and 53&#x00025; and 11 and 33&#x00025;, respectively (<xref rid="b15-ol-07-06-1987" ref-type="bibr">15</xref>). These values are much higher than those observed in a normal population, in which the prevalence of subclinical hypothyroidism is ~8&#x00025; in females and ~3&#x00025; in males, and where the prevalence of clinical hypothyroidism varies between 1&#x00025; and 2&#x00025; (<xref rid="b21-ol-07-06-1987" ref-type="bibr">21</xref>). Observation of the thyroid gland using ultrasonography during RT has identified vessel changes, which have been indicated to be associated with late radiation effects on this organ (<xref rid="b22-ol-07-06-1987" ref-type="bibr">22</xref>). Hypothyroidism is known to develop following a median interval of 1.4&#x02013;1.8 years, causing a progressively deteriorating quality of life with various clinical symptoms, including, fatigue, weakness, cold intolerance, weight gain, constipation and depression (<xref rid="b13-ol-07-06-1987" ref-type="bibr">13</xref>,<xref rid="b14-ol-07-06-1987" ref-type="bibr">14</xref>).</p>
<p>In a study involving only early-stage glottic cancer patients, the post-RT rates of subclinical and clinical hypothyroidism were reported to be 24 and 6&#x00025;, respectively (<xref rid="b23-ol-07-06-1987" ref-type="bibr">23</xref>). These rates do not appear to be low considering their relatively small target volume involving no neck node irradiation. Conventional RT consists of opposed-lateral beams to primarily avoid the spinal cord, however, it exposes a certain proportion of the thyroid gland (32.8&#x00025; on average in the present study) to high radiation doses almost identical to that of the target. To the best of our knowledge, the present study is the first to contour and restrict the dose not only to the carotid artery, but also to the thyroid gland, and revealed the dosimetric benefits of the advanced RT technique in terms of sparing the two organs. A small increase in the D<sub>max</sub> of the PTV with VMAT may affect larynx function (<xref rid="b7-ol-07-06-1987" ref-type="bibr">7</xref>), however, the V<sub>105</sub> was not significantly different between the two techniques. The spinal cord dose was increased, but remained within the recommended tolerable range.</p>
<p>Through acceleration of the atherosclerotic process of the carotid artery, RT may increase the risk of ischemic stroke in head and neck cancer patients (<xref rid="b24-ol-07-06-1987" ref-type="bibr">24</xref>). The actuarial incidences of cerebrovascular events at 10 years after definitive RT and surgery have been reported as 34&#x00025; and 26&#x00025;, respectively (P&lt;0.001) (<xref rid="b12-ol-07-06-1987" ref-type="bibr">12</xref>). When only the early-stage glottic cancer patients are assessed, RT is also associated with an increased risk of fatal cerebrovascular events compared with surgery, with a cumulative incidence at 15 years of 2.8 versus 1.5&#x00025; (P&#x0003D;0.024) (<xref rid="b25-ol-07-06-1987" ref-type="bibr">25</xref>). The results of the present study indicated that VMAT significantly decreases the dose to the carotid artery, which is consistent with previous dosimetric studies of IMRT or VMAT in early-stage glottic cancer (<xref rid="b5-ol-07-06-1987" ref-type="bibr">5</xref>&#x02013;<xref rid="b10-ol-07-06-1987" ref-type="bibr">10</xref>). A total of 35 Gy has been indicated as the threshold for intima media thickness and wall abnormalities of the carotid artery (<xref rid="b26-ol-07-06-1987" ref-type="bibr">26</xref>). In the present study, the V<sub>35</sub> was reduced by almost half (49&#x00025;) with VMAT. An additional radiation-related carotid toxicity is carotid blowout syndrome, a rare but devastating complication following reirradiation of the head and neck region for recurrence or a second malignancy (<xref rid="b27-ol-07-06-1987" ref-type="bibr">27</xref>). Therefore, it is important to minimize the unnecessary dose to the carotid artery during initial treatment.</p>
<p>In conclusion, compared with conventional RT, VMAT yields significantly improved dose-volume parameters of the thyroid gland and carotid artery, with no differences in target coverage or homogeneity. Considering the NTCP model for radiation-induced hypothyroidism (<xref rid="b20-ol-07-06-1987" ref-type="bibr">20</xref>), not only the carotid artery, but also the thyroid gland must be contoured and protected as an avoidance structure during advanced RT planning for early-stage glottic cancer. Considering the high rates of tumor control and the long-term survival of patients, favorable dosimetric features of organs associated with late-manifesting toxicities may be valuable.</p></sec></body>
<back>
<ack>
<title>Acknowledgements</title>
<p>This study was supported by the Soonchunhyang University Research Fund.</p></ack>
<ref-list>
<title>References</title>
<ref id="b1-ol-07-06-1987"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Higgins</surname><given-names>KM</given-names></name><name><surname>Shah</surname><given-names>MD</given-names></name><name><surname>Ogaick</surname><given-names>MJ</given-names></name><name><surname>Enepekides</surname><given-names>D</given-names></name></person-group><article-title>Treatment of early-stage glottic cancer: meta-analysis comparison of laser excision versus radiotherapy</article-title><source>J Otolaryngol Head Neck Surg</source><volume>38</volume><fpage>603</fpage><lpage>612</lpage><year>2009</year></element-citation></ref>
<ref id="b2-ol-07-06-1987"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Khan</surname><given-names>MK</given-names></name><name><surname>Koyfman</surname><given-names>SA</given-names></name><name><surname>Hunter</surname><given-names>GK</given-names></name><name><surname>Reddy</surname><given-names>CA</given-names></name><name><surname>Saxton</surname><given-names>JP</given-names></name></person-group><article-title>Definitive radiotherapy for early (T1-T2) glottic squamous cell carcinoma: a 20 year Cleveland clinic experience</article-title><source>Radiat Oncol</source><volume>7</volume><fpage>193</fpage><year>2012</year></element-citation></ref>
<ref id="b3-ol-07-06-1987"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mendenhall</surname><given-names>WM</given-names></name><name><surname>Amdur</surname><given-names>RJ</given-names></name><name><surname>Morris</surname><given-names>CG</given-names></name><name><surname>Hinerman</surname><given-names>RW</given-names></name></person-group><article-title>T1-T2N0 squamous cell carcinoma of the glottic larynx treated with radiation therapy</article-title><source>J Clin Oncol</source><volume>19</volume><fpage>4029</fpage><lpage>4036</lpage><year>2001</year></element-citation></ref>
<ref id="b4-ol-07-06-1987"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Feigenberg</surname><given-names>SJ</given-names></name><name><surname>Lango</surname><given-names>M</given-names></name><name><surname>Nicolaou</surname><given-names>N</given-names></name><name><surname>Ridge</surname><given-names>JA</given-names></name></person-group><article-title>Intensity-modulated radiotherapy for early larynx cancer: is there a role?</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>68</volume><fpage>2</fpage><lpage>3</lpage><year>2007</year></element-citation></ref>
<ref id="b5-ol-07-06-1987"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gomez</surname><given-names>D</given-names></name><name><surname>Cahlon</surname><given-names>O</given-names></name><name><surname>Mechalakos</surname><given-names>J</given-names></name><name><surname>Lee</surname><given-names>N</given-names></name></person-group><article-title>An investigation of intensity-modulated radiation therapy versus conventional two-dimensional and 3D-conformal radiation therapy for early stage larynx cancer</article-title><source>Radiat Oncol</source><volume>5</volume><fpage>74</fpage><year>2010</year></element-citation></ref>
<ref id="b6-ol-07-06-1987"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rosenthal</surname><given-names>DI</given-names></name><name><surname>Fuller</surname><given-names>CD</given-names></name><name><surname>Barker</surname><given-names>JL</given-names><suffix>Jr</suffix></name><etal/></person-group><article-title>Simple carotid-sparing intensity-modulated radiotherapy technique and preliminary experience for T1-2 glottic cancer</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>77</volume><fpage>455</fpage><lpage>461</lpage><year>2010</year></element-citation></ref>
<ref id="b7-ol-07-06-1987"><label>7</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chera</surname><given-names>BS</given-names></name><name><surname>Amdur</surname><given-names>RJ</given-names></name><name><surname>Morris</surname><given-names>CG</given-names></name><name><surname>Mendenhall</surname><given-names>WM</given-names></name></person-group><article-title>Carotid-sparing intensity-modulated radiotherapy for early-stage squamous cell carcinoma of the true vocal cord</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>77</volume><fpage>1380</fpage><lpage>1385</lpage><year>2010</year></element-citation></ref>
<ref id="b8-ol-07-06-1987"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Atalar</surname><given-names>B</given-names></name><name><surname>Gungor</surname><given-names>G</given-names></name><name><surname>Caglar</surname><given-names>H</given-names></name><name><surname>Aydin</surname><given-names>G</given-names></name><name><surname>Yapici</surname><given-names>B</given-names></name><name><surname>Ozyar</surname><given-names>E</given-names></name></person-group><article-title>Use of volumetric modulated arc radiotherapy in patients with early stage glottic cancer</article-title><source>Tumori</source><volume>98</volume><fpage>331</fpage><lpage>336</lpage><year>2012</year></element-citation></ref>
<ref id="b9-ol-07-06-1987"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Camingue</surname><given-names>P</given-names></name><name><surname>Christian</surname><given-names>R</given-names></name><name><surname>Ng</surname><given-names>D</given-names></name><name><surname>Williams</surname><given-names>P</given-names></name><name><surname>Amin</surname><given-names>M</given-names></name><name><surname>Roniger</surname><given-names>DL</given-names></name></person-group><article-title>Comparison of external beam treatment techniques for T1-2, N0, M0 glottic cancers</article-title><source>Med Dosim</source><volume>37</volume><fpage>221</fpage><lpage>224</lpage><year>2012</year></element-citation></ref>
<ref id="b10-ol-07-06-1987"><label>10</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Riegel</surname><given-names>AC</given-names></name><name><surname>Antone</surname><given-names>J</given-names></name><name><surname>Schwartz</surname><given-names>DL</given-names></name></person-group><article-title>Comparative dosimetry of volumetric modulated arc therapy and limited-angle static intensity-modulated radiation therapy for early-stage larynx cancer</article-title><source>Med Dosim</source><volume>38</volume><fpage>66</fpage><lpage>69</lpage><year>2013</year></element-citation></ref>
<ref id="b11-ol-07-06-1987"><label>11</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dorresteijn</surname><given-names>LD</given-names></name><name><surname>Kappelle</surname><given-names>AC</given-names></name><name><surname>Boogerd</surname><given-names>W</given-names></name><etal/></person-group><article-title>Increased risk of ischemic stroke after radiotherapy on the neck in patients younger than 60 years</article-title><source>J Clin Oncol</source><volume>20</volume><fpage>282</fpage><lpage>288</lpage><year>2002</year></element-citation></ref>
<ref id="b12-ol-07-06-1987"><label>12</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Smith</surname><given-names>GL</given-names></name><name><surname>Smith</surname><given-names>BD</given-names></name><name><surname>Buchholz</surname><given-names>TA</given-names></name><etal/></person-group><article-title>Cerebrovascular disease risk in older head and neck cancer patients after radiotherapy</article-title><source>J Clin Oncol</source><volume>26</volume><fpage>5119</fpage><lpage>5125</lpage><year>2008</year></element-citation></ref>
<ref id="b13-ol-07-06-1987"><label>13</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mercado</surname><given-names>G</given-names></name><name><surname>Adelstein</surname><given-names>DJ</given-names></name><name><surname>Saxton</surname><given-names>JP</given-names></name><name><surname>Secic</surname><given-names>M</given-names></name><name><surname>Larto</surname><given-names>MA</given-names></name><name><surname>Lavertu</surname><given-names>P</given-names></name></person-group><article-title>Hypothyroidism: a frequent event after radiotherapy and after radiotherapy with chemotherapy for patients with head and neck carcinoma</article-title><source>Cancer</source><volume>92</volume><fpage>2892</fpage><lpage>2897</lpage><year>2001</year></element-citation></ref>
<ref id="b14-ol-07-06-1987"><label>14</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tell</surname><given-names>R</given-names></name><name><surname>Lundell</surname><given-names>G</given-names></name><name><surname>Nilsson</surname><given-names>B</given-names></name><name><surname>Sj&#x000F6;din</surname><given-names>H</given-names></name><name><surname>Lewin</surname><given-names>F</given-names></name><name><surname>Lewensohn</surname><given-names>R</given-names></name></person-group><article-title>Long-term incidence of hypothyroidism after radiotherapy in patients with head-and-neck cancer</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>60</volume><fpage>395</fpage><lpage>400</lpage><year>2004</year></element-citation></ref>
<ref id="b15-ol-07-06-1987"><label>15</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Boomsma</surname><given-names>MJ</given-names></name><name><surname>Bijl</surname><given-names>HP</given-names></name><name><surname>Langendijk</surname><given-names>JA</given-names></name></person-group><article-title>Radiation-induced hypothyroidism in head and neck cancer patients: a systematic review</article-title><source>Radiother Oncol</source><volume>99</volume><fpage>1</fpage><lpage>5</lpage><year>2011</year></element-citation></ref>
<ref id="b16-ol-07-06-1987"><label>16</label><element-citation publication-type="book"><person-group person-group-type="editor"><name><surname>Edge</surname><given-names>SB</given-names></name><name><surname>Byrd</surname><given-names>DR</given-names></name><name><surname>Compton</surname><given-names>CC</given-names></name><name><surname>Fritz</surname><given-names>AG</given-names></name><name><surname>Greene</surname><given-names>FL</given-names></name><name><surname>Trotti</surname><given-names>A</given-names></name></person-group><source>AJCC Cancer Staging Manual</source><edition>7th edition</edition><publisher-name>Springer</publisher-name><publisher-loc>New York, NY</publisher-loc><year>2010</year></element-citation></ref>
<ref id="b17-ol-07-06-1987"><label>17</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Verbakel</surname><given-names>WF</given-names></name><name><surname>Cuijpers</surname><given-names>JP</given-names></name><name><surname>Hoffmans</surname><given-names>D</given-names></name><name><surname>Bieker</surname><given-names>M</given-names></name><name><surname>Slotman</surname><given-names>BJ</given-names></name><name><surname>Senan</surname><given-names>S</given-names></name></person-group><article-title>Volumetric intensity-modulated arc therapy vs. conventional IMRT in head-and-neck cancer: a comparative planning and dosimetric study</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>74</volume><fpage>252</fpage><lpage>259</lpage><year>2009</year></element-citation></ref>
<ref id="b18-ol-07-06-1987"><label>18</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Emami</surname><given-names>B</given-names></name><name><surname>Lyman</surname><given-names>J</given-names></name><name><surname>Brown</surname><given-names>A</given-names></name><etal/></person-group><article-title>Tolerance of normal tissue to therapeutic irradiation</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>21</volume><fpage>109</fpage><lpage>122</lpage><year>1991</year></element-citation></ref>
<ref id="b19-ol-07-06-1987"><label>19</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Marks</surname><given-names>LB</given-names></name><name><surname>Yorke</surname><given-names>ED</given-names></name><name><surname>Jackson</surname><given-names>A</given-names></name><etal/></person-group><article-title>Use of normal tissue complication probability models in the clinic</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>76</volume><issue>Suppl 3</issue><fpage>S10</fpage><lpage>S19</lpage><year>2010</year></element-citation></ref>
<ref id="b20-ol-07-06-1987"><label>20</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Boomsma</surname><given-names>MJ</given-names></name><name><surname>Bijl</surname><given-names>HP</given-names></name><name><surname>Christianen</surname><given-names>ME</given-names></name><etal/></person-group><article-title>A prospective cohort study on radiation-induced hypothyroidism: development of an NTCP model</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>84</volume><fpage>e351</fpage><lpage>e356</lpage><year>2012</year></element-citation></ref>
<ref id="b21-ol-07-06-1987"><label>21</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Vanderpump</surname><given-names>MP</given-names></name><name><surname>Tunbridge</surname><given-names>WM</given-names></name></person-group><article-title>Epidemiology and prevention of clinical and subclinical hypothyroidism</article-title><source>Thyroid</source><volume>12</volume><fpage>839</fpage><lpage>847</lpage><year>2002</year></element-citation></ref>
<ref id="b22-ol-07-06-1987"><label>22</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bakhshandeh</surname><given-names>M</given-names></name><name><surname>Hashemi</surname><given-names>B</given-names></name><name><surname>Mahdavi</surname><given-names>SR</given-names></name><name><surname>Nikoofar</surname><given-names>A</given-names></name><name><surname>Edraki</surname><given-names>HR</given-names></name><name><surname>Kazemnejad</surname><given-names>A</given-names></name></person-group><article-title>Evaluation of thyroid disorders during head-and-neck radiotherapy by using functional analysis and ultrasonography</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>83</volume><fpage>198</fpage><lpage>203</lpage><year>2012</year></element-citation></ref>
<ref id="b23-ol-07-06-1987"><label>23</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kumar</surname><given-names>S</given-names></name><name><surname>Moorthy</surname><given-names>R</given-names></name><name><surname>Dhanasekar</surname><given-names>G</given-names></name><name><surname>Thompson</surname><given-names>S</given-names></name><name><surname>Griffiths</surname><given-names>H</given-names></name></person-group><article-title>The incidence of thyroid dysfunction following radiotherapy for early stage carcinoma of the larynx</article-title><source>Eur Arch Otorhinolaryngol</source><volume>268</volume><fpage>1519</fpage><lpage>1522</lpage><year>2011</year></element-citation></ref>
<ref id="b24-ol-07-06-1987"><label>24</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gianicolo</surname><given-names>ME</given-names></name><name><surname>Gianicolo</surname><given-names>EA</given-names></name><name><surname>Tramacere</surname><given-names>F</given-names></name><name><surname>Andreassi</surname><given-names>MG</given-names></name><name><surname>Portaluri</surname><given-names>M</given-names></name></person-group><article-title>Effects of external irradiation of the neck region on intima media thickness of the common carotid artery</article-title><source>Cardiovasc Ultrasound</source><volume>8</volume><fpage>8</fpage><year>2010</year></element-citation></ref>
<ref id="b25-ol-07-06-1987"><label>25</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Swisher-McClure</surname><given-names>S</given-names></name><name><surname>Mitra</surname><given-names>N</given-names></name><name><surname>Lin</surname><given-names>A</given-names></name><etal/></person-group><article-title>Risk of fatal cerebrovascular accidents after external beam radiation therapy for early stage glottic larynx cancer</article-title><source>Head Neck</source><month>Apr</month><day>18</day><year>2013</year><comment>(Epub ahead of print)</comment><pub-id pub-id-type="doi">10.1002/hed.23342</pub-id></element-citation></ref>
<ref id="b26-ol-07-06-1987"><label>26</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Martin</surname><given-names>JD</given-names></name><name><surname>Buckley</surname><given-names>AR</given-names></name><name><surname>Graeb</surname><given-names>D</given-names></name><name><surname>Walman</surname><given-names>B</given-names></name><name><surname>Salvian</surname><given-names>A</given-names></name><name><surname>Hay</surname><given-names>JH</given-names></name></person-group><article-title>Carotid artery stenosis in asymptomatic patients who have received unilateral head-and-neck irradiation</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>63</volume><fpage>1197</fpage><lpage>1205</lpage><year>2005</year></element-citation></ref>
<ref id="b27-ol-07-06-1987"><label>27</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>McDonald</surname><given-names>MW</given-names></name><name><surname>Moore</surname><given-names>MG</given-names></name><name><surname>Johnstone</surname><given-names>PA</given-names></name></person-group><article-title>Risk of carotid blowout after reirradiation of the head and neck: a systematic review</article-title><source>Int J Radiat Oncol Biol Phys</source><volume>82</volume><fpage>1083</fpage><lpage>1089</lpage><year>2012</year></element-citation></ref></ref-list></back>
<floats-group>
<fig id="f1-ol-07-06-1987" position="float">
<label>Figure 1</label>
<caption>
<p>Comparison of the isodose distributions of the two RT techniques in a representative case. (A) VMAT and (B) conventional RT axial plan CT images at the mid-PTV (red) level showing the carotid artery (green). (C) VMAT and (D) conventional RT axial plan CT images at the lower PTV level showing the thyroid gland (blue). RT, radiotherapy; VMAT, volumetric modulated arc therapy; CT, computed tomography; PTV, planning target volume.</p></caption>
<graphic xlink:href="OL-07-06-1987-g00.gif"/></fig>
<fig id="f2-ol-07-06-1987" position="float">
<label>Figure 2</label>
<caption>
<p>Comparison of dose-volume histograms of the two RT techniques in a representative case &#x0005B;VMAT (triangles) vs. conventional RT (squares)&#x0005D;. The planning target volume (red), carotid artery (green), thyroid gland (blue) and spinal cord (orange) are shown. VMAT, volumetric modulated arc therapy; RT, radiotherapy.</p></caption>
<graphic xlink:href="OL-07-06-1987-g01.gif"/></fig>
<table-wrap id="tI-ol-07-06-1987" position="float">
<label>Table I</label>
<caption>
<p>Comparison of the PTV dosimetric parameters between VMAT and conventional RT (n&#x0003D;15).</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="bottom">Parameters</th>
<th align="center" valign="bottom">VMAT, mean &#x000B1; SD (range)</th>
<th align="center" valign="bottom">Conventional RT, mean &#x000B1; SD (range)</th>
<th align="center" valign="bottom">P-value<xref rid="tfn1-ol-07-06-1987" ref-type="table-fn">a</xref></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="top">D<sub>min</sub>, Gy</td>
<td align="center" valign="top">50.0&#x000B1;2.6 (45.1&#x02013;52.9)</td>
<td align="right" valign="top">51.6&#x000B1;4.2 (45.2&#x02013;56.8)</td>
<td align="center" valign="top">0.214</td></tr>
<tr>
<td align="left" valign="top">D<sub>max</sub>, Gy</td>
<td align="center" valign="top">66.8&#x000B1;1.3 (65.4&#x02013;70.1)</td>
<td align="right" valign="top">65.7&#x000B1;0.6 (64.9&#x02013;66.5)</td>
<td align="center" valign="top">0.074</td></tr>
<tr>
<td align="left" valign="top">D<sub>mean</sub>, Gy</td>
<td align="center" valign="top">62.8&#x000B1;0.6 (62.1&#x02013;64.5)</td>
<td align="right" valign="top">62.8&#x000B1;0.4 (62.0&#x02013;63.3)</td>
<td align="center" valign="top">0.236</td></tr>
<tr>
<td align="left" valign="top">V<sub>105</sub>, &#x00025;</td>
<td align="center" valign="top">1.7&#x000B1;5.4 (0.0&#x02013;17.0)</td>
<td align="right" valign="top">0.005&#x000B1;0.01 (0.0&#x02013;0.05)</td>
<td align="center" valign="top">0.116</td></tr></tbody></table>
<table-wrap-foot><fn id="tfn1-ol-07-06-1987">
<label>a</label>
<p>Wilcoxon signed-rank test.</p></fn><fn id="tfn2-ol-07-06-1987">
<p>PTV, planning target volume; VMAT, volumetric modulated arc therapy; RT, radiotherapy; SD, standard deviation; D<sub>min</sub>, minimum dose; D<sub>max</sub>, maximum dose; D<sub>mean</sub>, mean dose; V<sub>105</sub>, volume receiving &#x02265;105&#x00025; of the prescription dose.</p></fn></table-wrap-foot></table-wrap>
<table-wrap id="tII-ol-07-06-1987" position="float">
<label>Table II</label>
<caption>
<p>Comparison of the OAR dosimetric parameters between VMAT and conventional RT (n&#x0003D;15).</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th align="left" valign="bottom">Parameters</th>
<th align="center" valign="bottom">VMAT, mean &#x000B1; SD (range)</th>
<th align="center" valign="bottom">Conventional RT, mean &#x000B1; SD (range)</th>
<th align="center" valign="bottom">P-value<xref rid="tfn3-ol-07-06-1987" ref-type="table-fn">a</xref></th></tr></thead>
<tbody>
<tr>
<td colspan="4" align="left" valign="top">Thyroid gland</td></tr>
<tr>
<td align="left" valign="top">&#x02003;D<sub>mean</sub>, Gy</td>
<td align="center" valign="top">14.7&#x000B1;2.6 (10.2&#x02013;18.0)</td>
<td align="center" valign="top">22.2&#x000B1;3.9 (15.8&#x02013;26.5)</td>
<td align="center" valign="top">&lt;0.01</td></tr>
<tr>
<td align="left" valign="top">&#x02003;V<sub>30</sub>, &#x00025;</td>
<td align="center" valign="top">19.2&#x000B1;4.0 (12.0&#x02013;26.2)</td>
<td align="center" valign="top">31.7&#x000B1;6.2 (21.5&#x02013;37.8)</td>
<td align="center" valign="top">&lt;0.01</td></tr>
<tr>
<td align="left" valign="top">&#x02003;V<sub>50</sub>, &#x00025;</td>
<td align="center" valign="top">13.8&#x000B1;3.8 (8.0&#x02013;19.4)</td>
<td align="center" valign="top">26.7&#x000B1;5.9 (17.0&#x02013;32.6)</td>
<td align="center" valign="top">&lt;0.01</td></tr>
<tr>
<td colspan="4" align="left" valign="top">Carotid artery</td></tr>
<tr>
<td align="left" valign="top">&#x02003;D<sub>mean</sub>, Gy</td>
<td align="center" valign="top">15.7&#x000B1;3.1 (10.6&#x02013;20.2)</td>
<td align="center" valign="top">28.8&#x000B1;6.9 (16.8&#x02013;39.9)</td>
<td align="center" valign="top">&lt;0.01</td></tr>
<tr>
<td align="left" valign="top">&#x02003;V<sub>35</sub>, &#x00025;</td>
<td align="center" valign="top">21.1&#x000B1;6.4 (11.6&#x02013;32.3)</td>
<td align="center" valign="top">41.1&#x000B1;10.5 (24.1&#x02013;58.7)</td>
<td align="center" valign="top">&lt;0.01</td></tr>
<tr>
<td align="left" valign="top">&#x02003;V<sub>50</sub>, &#x00025;</td>
<td align="center" valign="top">2.8&#x000B1;2.0 (0.0&#x02013;6.0)</td>
<td align="center" valign="top">38.2&#x000B1;10.2 (22.0&#x02013;55.2)</td>
<td align="center" valign="top">&lt;0.01</td></tr>
<tr>
<td colspan="4" align="left" valign="top">Spinal cord</td></tr>
<tr>
<td align="left" valign="top">&#x02003;D<sub>max</sub>, Gy</td>
<td align="center" valign="top">29.8&#x000B1;1.9 (25.9&#x02013;33.0)</td>
<td align="center" valign="top">3.3&#x000B1;0.8 (2.1&#x02013;4.8)</td>
<td align="center" valign="top">&lt;0.01</td></tr></tbody></table>
<table-wrap-foot><fn id="tfn3-ol-07-06-1987">
<label>a</label>
<p>Wilcoxon signed-rank test.</p></fn><fn id="tfn4-ol-07-06-1987">
<p>OAR, organ at risk; VMAT, volumetric modulated arc therapy; RT, radiotherapy; SD, standard deviation; V<sub>30</sub>, volume receiving &#x02265;30&#x00025; of the prescription dose; D<sub>mean</sub>, mean dose; D<sub>max</sub>, maximum dose.</p></fn></table-wrap-foot></table-wrap></floats-group></article>