Effects of respiratory motion on volumetric and positional difference of GTV in lung cancer based on 3DCT and 4DCT scanning

  • Authors:
    • Shijiang Wang
    • Dongping Shang
    • Xue Meng
    • Xindong Sun
    • Yan Ma
    • Jinming Yu
  • View Affiliations

  • Published online on: December 18, 2018     https://doi.org/10.3892/ol.2018.9844
  • Pages: 2388-2392
  • Copyright: © Wang et al. This is an open access article distributed under the terms of Creative Commons Attribution License.

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

Differences in gross target volume (GTV) and central point positions among moving lung cancer models constructed by CT scanning at different frequencies were compared, in order to explore the effect of different respiratory frequencies on the GTV constructions in moving lung tumors. Eight models in different shapes and sizes were established to stimulate lung tumors. The three-dimensional computed tomography (3DCT) and four-dimensional computed tomography (4DCT) scanning were performed at 10, 15 and 20 times/min in different models. Differences in GTV volumes and central point positions at different motion frequencies were compared by means of GTV3Ds (GTV3D-10, GTV3D-15, GTV3D-20) and IGTV4Ds (IGTV4D-10, IGTV4D-15, IGTV4D-20). Volumes of GTV3D-10, GTV3D-15, GTV3D-20 were 12.41±14.26, 10.38±11.18 and 12.50±15.23 cm3 respectively (P=0.687). Central point coordinates in the x-axis direction were -8.16±96.21, -8.57±96.08 and -8.56±95.73 respectively (P=0.968). Central point coordinates in the y-axis direction were 108.22±25.03, 110.41±22.47 and 109.04±24.24 (P=0.028). Central point coordinates in the z-axis direction were 65.19±13.68, 65.43±13.40 and 65.38±13.17 (P=0.902). The difference was significant in the y-axis direction (P=0.028). Volumes of IGTV4D-10, IGTV4D‑15, IGTV4D-20 were 17.78±19.42, 17.43±19.56 and 17.44±18.80 cm3 (P=0.417). Central point coordinates in the x-axis direction were -7.73±95.93, -7.86±95.56 and -7.92±95.14 (P=0.325). Central point coordinates in the y-axis direction were 109.41±24.54, 109.60±24.13 and 109.16±24.28 (P=0.525). Central point coordinates in the z-axis direction were 65.52±13.31, 65.59±13.39 and 65.51±13.34 (P=0.093). However, the central point position of GTV in the head and foot direction by 3DCT scanning was severely affected by the respiratory frequency.
View References

Related Articles

Journal Cover

February-2019
Volume 17 Issue 2

Print ISSN: 1792-1074
Online ISSN:1792-1082

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Wang S, Shang D, Meng X, Sun X, Ma Y and Yu J: Effects of respiratory motion on volumetric and positional difference of GTV in lung cancer based on 3DCT and 4DCT scanning. Oncol Lett 17: 2388-2392, 2019
APA
Wang, S., Shang, D., Meng, X., Sun, X., Ma, Y., & Yu, J. (2019). Effects of respiratory motion on volumetric and positional difference of GTV in lung cancer based on 3DCT and 4DCT scanning. Oncology Letters, 17, 2388-2392. https://doi.org/10.3892/ol.2018.9844
MLA
Wang, S., Shang, D., Meng, X., Sun, X., Ma, Y., Yu, J."Effects of respiratory motion on volumetric and positional difference of GTV in lung cancer based on 3DCT and 4DCT scanning". Oncology Letters 17.2 (2019): 2388-2392.
Chicago
Wang, S., Shang, D., Meng, X., Sun, X., Ma, Y., Yu, J."Effects of respiratory motion on volumetric and positional difference of GTV in lung cancer based on 3DCT and 4DCT scanning". Oncology Letters 17, no. 2 (2019): 2388-2392. https://doi.org/10.3892/ol.2018.9844