Open Access

Analysis of real-time three dimensional transesophageal echocardiography in the assessment of left atrial appendage function in patients with atrial fibrillation

  • Authors:
    • Lin Gan
    • Lan Yu
    • Manying Xie
    • Wei Feng
    • Jiabao Yin
  • View Affiliations

  • Published online on: September 23, 2016     https://doi.org/10.3892/etm.2016.3745
  • Pages: 3323-3327
  • Copyright: © Gan et al. This is an open access article distributed under the terms of Creative Commons Attribution License.

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

The aim of the study was to examine changes in left atrial appendage volume (LAA-V) in patients with non-valvular atrial fibrillation (AF) using real-time three-dimensional transesophageal echocardiography (RT3D-TEE) and evaluate the prediction value on the high risk of thrombosis of LAA. Using RT3D-TEE we measured: i) LAA peak empty velocity (LAA‑PEV), ii) LAA-V including LAA end-diastolic volume (LAA‑EDV) and end-systolic volume (LAA-ESV). We also calculated LAA ejection fraction (LAA-EF). RT3D-TEE was applied in 20 control cases and 74 patients with non‑valvular AF. According to the presence of thrombosis, 74 patients were divided into the no thrombosis group (NTH group, n=52) and thrombosis group (TH group, n=22). Our results showed that there were significant differences in LAA-V and LAA-EF values in different groups (P<0.05). LAA-EDV moderately correlated with LAA-PEV (r=-0.531, P<0.001) while LAA-ESV demonstrated a strong correlation with LAA-PEV (r=-0.741, P<0.001). LAA-EF also showed a strong correlation with LAA-PEV (r=0.693, P<0.001). Through receiver operating characteristic (ROC) curves, the cut-off values of LAA-EDV and LAA-ESV in thrombosis of LAA were 18.45 and 9.69 ml, respectively. RT3D-TEE effectively evaluated the LAA-V, LAA-PEV and LAA-EF parameters, and proved to be valuable in the process of evaluation of thrombosis of LAA.
View Figures
View References

Related Articles

Journal Cover

November-2016
Volume 12 Issue 5

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Gan L, Yu L, Xie M, Feng W and Yin J: Analysis of real-time three dimensional transesophageal echocardiography in the assessment of left atrial appendage function in patients with atrial fibrillation. Exp Ther Med 12: 3323-3327, 2016
APA
Gan, L., Yu, L., Xie, M., Feng, W., & Yin, J. (2016). Analysis of real-time three dimensional transesophageal echocardiography in the assessment of left atrial appendage function in patients with atrial fibrillation. Experimental and Therapeutic Medicine, 12, 3323-3327. https://doi.org/10.3892/etm.2016.3745
MLA
Gan, L., Yu, L., Xie, M., Feng, W., Yin, J."Analysis of real-time three dimensional transesophageal echocardiography in the assessment of left atrial appendage function in patients with atrial fibrillation". Experimental and Therapeutic Medicine 12.5 (2016): 3323-3327.
Chicago
Gan, L., Yu, L., Xie, M., Feng, W., Yin, J."Analysis of real-time three dimensional transesophageal echocardiography in the assessment of left atrial appendage function in patients with atrial fibrillation". Experimental and Therapeutic Medicine 12, no. 5 (2016): 3323-3327. https://doi.org/10.3892/etm.2016.3745