Open Access

Efficacy of nickel‑titanium memory alloy in the treatment of multiple rib fracture combined with sternal fracture

  • Authors:
    • Ming Xiong
    • Wei Hu
    • Qiang Lou
    • Shi Yin
    • Xin Wang
  • View Affiliations

  • Published online on: May 22, 2019     https://doi.org/10.3892/etm.2019.7597
  • Pages: 537-542
  • Copyright: © Xiong et al. This is an open access article distributed under the terms of Creative Commons Attribution License.

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

Clinical efficacy and complications of nickel‑titanium memory alloy in the treatment of multiple rib fractures combined with sternal fractures was investigated. A retrospective analysis of 123 patients with multiple rib fractures combined with sternal fractures admitted to First People's Hospital of Fuzhou from January 2013 to December 2015 was performed, including study group (treated with internal fixation by the nickel‑titanium memory alloy, n=68) and control group (treated with internal fixation by partial pressure bandage, n=55). Μean arterial pressure (MAP), heart rate (HR), and visual analogue pain score (VAS) of the two groups before and after treatment were compared and analyzed. No significant difference in MAP, HR and VAS scores between groups was detected before treatment (P>0.05). Αfter treatment, MAP score of study group was significantly higher, and HR and VAS scores were significantly lower (P<0.05). Μethod of internal fixation by the nickel‑titanium memory alloy, with better efficacy than the traditional method of internal fixation by partial pressure bandage and less postoperative complications in the treatment of flail chest caused by multiple rib fractures combined with sternal fractures, is worthy of clinical application and promotion.

Introduction

Severe closed chest injury in patients caused by multiple rib and sternal fractures often lead to flail chest (1) which is one of the six main causes of early death caused by thoracic trauma to seriously endanger human life (2). With unsupported thoracic wall due to fractured ribs, and critical clinical symptoms such as abnormal respiratory, induced acute respiratory distress syndrome or multiple organ failure, patients with flail chest usually are hard to cure, thus suffering from a high mortality rate (35).

At present, stent traction, simple partial pressure bandage or internal fixation by partial pressure bandage assisted by ventilator are the main treatments for the flail chest caused by multiple rib fractures (6). However, after the above conservative treatments, patients often suffer from accumulated secretions in the respiratory tract, chest pain, tachypnea, and even dyspnea aroused from too long bed rest that will increase the risk of parenchymatous pneumonia such as acute pneumonia and persistent pneumonia, and also suffer from muscular atrophy due to easily occurring incomplete transposition or complete fractures, vulnerable to complications or recurrence of disease after treatment (7,8). With the innovation of medical technology and the advanced internal fixer with better performance, the nickel-titanium memory alloy internal fixer, has high safety, stability, maneuverability and convenience, which is able to narrow the wound, is a new type of treatment device for the flail chest (9,10). So far few studies on the efficacy of the method of internal fixation by the nickel-titanium memory alloy and the method of internal fixation by the partial pressure bandage in treating the flail chest caused by multiple rib fractures combined with sternal fractures have been reported, which inspired this study to investigate the efficacy of these two methods in the treatment of patients with multiple rib fractures combined with sternal fractures and make comparison of the postoperative adverse reactions and complications between the two methods.

Patients and methods

Patient information

This study retrospectively analyzed 123 patients with multiple rib and sternal fractures admitted to the First People's Hospital of Fuzhou (Fuzhou, China) from January 2013 to December 2015. Among them, 68 patients (43 males and 25 females) treated with internal fixation by the nickel-titanium memory alloy were enrolled in study group, aged 18 to 71 years, with a mean age of 46.63±5.47 years; 55 patients (39 males and 16 females) treated with internal fixation by partial pressure bandage were enrolled in control group, aged 19 to 73 years, with a mean age of 47.81±4.37 years. Inclusion criteria: i) patients diagnosed with multiple rib and sternal fractures; ii) patients with complete medical records; iii) patients older than 18 years; and iv) patients with no relevant treatment history in other hospitals. Exclusion criteria: i) patients unwilling to cooperate with the medical care; ii) patients who were transferred to other hospitals or died during the hospitalization; iii) patients with other respiratory diseases; iv) patients with acute gastrointestinal bleeding; v) patients with cardiac, mediastinal and macrovascular injuries; vi) patients with one or more tumors; and vii) patients with mental disorders and cognitive impairment. All the study subjects and their families signed an informed consent and cooperated with medical staff to complete the relevant medical treatment.

The study was approved by the Ethics Committee of First People's Hospital of Fuzhou. Patients who participated in this research had complete clinical data. The signed informed consents were obtained from the patients or the guardians.

Methods

PROSIM8 monitor made by Fluke Corporation (Everett, WA, USA) was connected to all patients after the admission to monitor their mean arterial pressure (MAP) and heart rate (HR). In control group treated with internal fixation by partial pressure bandage, first the drainage treatment was performed to prevent pneumothorax, then the chest wall was compressed by the fixed sterilized cotton pad, after that the ventilator was used with positive end expiratory pressure at 6–8 mmHg of oxygen. In study group, under the general anesthesia, the relevant ribs were fixed with method of key-point fixation according to the support conditions of the thoracic. After reduction of fractured ribs, the appropriate type of nickel-titanium memory alloy embracing device (Lanzhou Seemine SMA Co., Ltd., Lanzhou, China) was fixed to the fractured ribs. After fixation was well done, closed drainage tube was routinely placed. Then, comparison was performed between the two groups in terms of efficacy, hemodynamics, visual analogue pain score (VAS), and occurrence rate of adverse reactions 5 days after treatment, and hospitalization time.

Evaluation criteria

Efficacy evaluation criteria (11): i) Significant efficacy: normal clinical symptoms, physical signs and imaging examination results; ii) certain efficacy: improved clinical symptoms and physical signs, with slightly abnormal imaging examination results; iii) stable condition: no obviously relieved clinical symptoms and physical signs, with unchanged imaging examination results; iv) no efficacy: unusually aggravated clinical symptoms and physical signs, with abnormal imaging examination results. Clinical overall efficiency = (number of patients with significant efficacy + number of patients with certain efficacy)/total number of cases ×100%.

VAS assessment criteria (12): VAS score ranged from 0–10 points, higher the score, higher the patient's pain index.

Statistical analysis

Statistical analysis was carried out using SPSS19.1 software system (IBM Corp., Armonk, NY, USA). Count data were expressed as the percentage [n (%)]. Difference between two groups was measured by χ2 test. Measurement data were expressed as mean ± standard deviation (SD). Difference between two groups was compared by t-test, so was the difference between the conditions before and after treatment in one group. P<0.05 was considered to indicate a statistically significant difference.

Results

Comparison of the clinical data of patients in the two groups

To ensure accuracy and credibility of experimental results, patients selected into the two groups were not statistically different in basic clinical such as sex, age, weight, type of sternal fracture, location of sternal fracture and cause of injury. There was no statistical significance (P>0.05), indicating that the two groups of patients were comparable. See Table I for details of patients' basic information.

Table I.

Basic information of patients in study and control group [n (%)].

Table I.

Basic information of patients in study and control group [n (%)].

GroupStudy (n=68)Control (n=55)χ2P-value
Sex 0.8060.369
  Male43 (63.24)39 (70.91)
  Female25 (36.76)16 (29.09)
Age (year) 3.1280.077
  ≤4529 (42.65)15 (27.27)
  >4539 (57.35)40 (72.73)
Weight (kg) 0.1940.660
  ≤6027 (39.71)24 (43.64)
  >6041 (60.29)31 (56.36)
Type of sternal fracture 0.3870.534
  Transverse fracture31 (45.59)22 (40.00)
  Oblique fracture37 (54.41)33 (60.00)
Location of sternal fracture 0.2620.755
  Gladiolus50 (73.53)40 (72.73)
  Manubrium13 (19.12)  9 (16.36)
  Sternal angle5 (7.35)  6 (10.91)
Cause of injury 0.6500.723
  Traffic54 (79.41)43 (78.18)
  Blunt  8 (11.76)5 (9.09)
  Falling6 (8.82)  7 (12.73)
Comparison of MAP between study and control group before and after admission to hospital

No significant difference in MAP between the two groups was shown before treatment (P>0.05). After treatment, MAP of the study group was statistically significantly higher than that of control group (P<0.05). MAPs in both study and control group after treatment were higher than those before treatment, with difference being statistically significant (P<0.05; Table II).

Table II.

Comparison of MAP between study and control group before and after admission to hospital (mmHg).

Table II.

Comparison of MAP between study and control group before and after admission to hospital (mmHg).

IndexStudy group (n=68)Control group (n=55)tP-value
Before treatment   83.95±13.3883.68±12.790.114   0.910
After treatment117.83±15.3699.23±14.476.852<0.001
t13.72   5.971
P-value   <0.001<0.001

[i] MAP, mean arterial pressure.

Comparison of HR between study and control group before and after admission to hospital

No significant difference in the HR between the two groups was shown before treatment (P>0.05). After treatment, HR of study group was statistically significantly lower than that of control group (P<0.05). HRs in both study and control group after treatment were lower than those before treatment, with statistical difference between them (P<0.05; Table III).

Table III.

Comparison of HR between study and control group before and after admission to hospital (beat/min).

Table III.

Comparison of HR between study and control group before and after admission to hospital (beat/min).

IndexStudy group (n=68)Control group (n=55)tP-value
Before treatment115.21±10.35   116.39±11.12   0.608   0.544
After treatment84.62±8.24102.51±9.2811.31<0.001
t19.070   7.107
P-value<0.001<0.001

[i] HR, heart rate.

Comparison of VAS between study and control group before and after admission to hospital

No significant difference in VAS between the two groups was shown before treatment (P>0.05). After treatment, VAS of study group was statistically significantly lower than that of control group (P<0.05). VAS scores in both study and control groups after treatment were lower than those before treatment, and difference was statistically significant (P<0.05; Table IV).

Table IV.

Comparison of the VAS between study and control group before and after admission to hospital.

Table IV.

Comparison of the VAS between study and control group before and after admission to hospital.

GroupStudy (n=68)Control (n=55)tP-value
Before the treatment7.65±2.217.48±2.480.402   0.689
After the treatment2.14±0.863.74±1.138.915<0.001
t19.16017.360
P-value<0.001<0.001

[i] VAS, visual analogue pain score.

Comparison of hospitalization time between study and control group

Hospitalization time of study group (18.63±2.17 days) was much lower than that of control group (24.28±3.62 days), and the two were statistically different (t=10.71, P<0.001; Fig. 1).

Comparison of efficacy between study and control group

The overall effective rate of study group was much higher than that of control group, and difference was statistically significant (P<0.05; Table V).

Table V.

Comparison of the efficacy between study and control group [n (%)].

Table V.

Comparison of the efficacy between study and control group [n (%)].

Effective degreeStudy (n=68)Control (n=55)χ2P-value
Significant efficacy11 (16.18)  8 (14.55)0.0620.804
Certain efficacy47 (69.12)30 (54.55)2.7580.097
Stable situation  7 (10.29)11 (20.00)2.2930.130
No efficacy3 (4.41)  6 (10.91)1.8930.169
Overall effective rate58 (85.29)38 (69.09)4.6600.031
Comparison of occurrence of complications and adverse reactions in study and control group

The number of patients with pulmonary infection in study group was significantly lower than that of control group, with a recognized statistical difference (P<0.05). The number of patients with adverse reactions such as atelectasis and sternal malformation in study group was smaller than that in control group, but they were not statistically different (P>0.05; Table VI).

Table VI.

Comparison of the occurrence of complications and adverse reactions in study and control group [n (%)].

Table VI.

Comparison of the occurrence of complications and adverse reactions in study and control group [n (%)].

GroupStudy (n=68)Control (n=55)χ2P-value
Pulmonary infection5 (7.35)11 (20.00)4.2980.038
Atelectasis1 (1.47)4 (7.27)2.6250.105
Sternal malformation3 (4.41)5 (9.09)1.0950.295
Others2 (2.94)  6 (10.91)3.1750.075

Discussion

Multiple rib fractures, a kind of closed injuries in thoracic surgery, often occurs in severe traffic accidents or severe crush injuries (13,14). According to Yang et al (15), mortality rate of the flail chest is approximately 16% which is increased if the flail chest is combined with a sternal fracture (16). Industry stepping into the advanced stage, multiple rib fractures combined with sternal fractures, with a rocketing growth of incidence rate and severe damage to human health, have become the focus of modern medicine (9,17). The advancement of the new internal fixation equipment makes the operation of patients with fractures easier and safer, for example, the nickel-titanium memory alloy, with its good histocompatibility to be deformed and deployed at low temperature and to automatically restore the original shape at body temperature, is of great help for the convenience of the fixation, the shortening of the operation time, the decrease of injuries around the fracture, and the maintenance of effective blood circulation. Different arced embracing device are chosen according to different fraction sties. The embracing device, which can fix the ribs at multiple points and collectively surround the rib to generate the embracing force, is able to make it harder for the fracture end to rotate and shift, and cause no obvious adverse reactions to the human body, thus meeting the requirements of the implant materials for human body (18,19). Two methods were studied of internal fixation by the nickel-titanium memory alloy and by the partial pressure bandage in treating patients with multiple rib fractures and sternal fractures, and analyzed the difference between the two groups in terms of the hospitalization time, efficacy, occurrence rate of postoperative complications, and the MAP, HR and VAS scores before and after the treatment, to provide effective reference and guidance for the future treatment of the disease.

Results of this study showed no significant difference in MAP and HR between the two groups before treatment, but revealed statistical difference after treatment that the MAP and HR indexes in study group were in greatly better conditions than those in control group, thus, after treatment, MAP in study group was higher than that in control group, while HR in study group was lower than that in control group, and differences were statistically significant. In study group, where the patients were treated with internal fixation by the nickel-titanium memory alloy to get the dislocated ribs and sternal fractures reset and internally fixed, the deformed thorax of the patient was restored to its original shape and function, and abnormal breathing disorder and compressive cardiac tamponade of the patient were eliminated (20), with more pleasing MAP, HR indicators, postoperative efficacy, and incidence of chest deformity compared to control group and that before treatment. In control group, non-operative treatment brought no complete relief to the patient's abnormal breathing and caused different degrees of softening, collapse, and instability of sternal wall that added severe pain to the even slight movement of patients (21), with a statistically significantly higher VAS score than that of study group. Some literature reported that the needs for analgesia between patients treated with rib fracture surgery and non-surgical patients were not different before treatment, but after treatment, patients who underwent surgery required fewer analgesics than non-surgical patients (22). With internal fixation, patients in study group had free movement and sputum, which is conducive to the maintenance of a clear airway to reduce the incidence of postoperative pulmonary infection and atelectasis (23); while in the control group, patients might suffer from respiratory muscle atrophy with the use of the ventilator, and were incapable of timely sputum excretion due to severe pain or inconvenient movement, prone to atelectasis and repeated pulmonary infection (24), which contributed to longer hospitalization time and more cases of pulmonary infection and atelectasis in control group than study group. Study by Zhang et al (25) proved that patients who underwent surgical treatment of flail chest and pulmonary contusion enjoyed a shorter hospitalization time than non-surgical patients, which agrees with the results of this study.

Shortcomings of this experiment surfaced due to limited experimental conditions, for example, the sample size of the research objects was small for statistical analysis, furthermore, the possible differences in different ethnic groups were not studied. A longer-term follow-up survey is also required.

In summary, the clinical efficacy of the internal fixation by the nickel-titanium memory alloy for the treatment of multiple rib fractures and sternal fractures was better than the traditional method of partial pressure bandage, with fewer postoperative complications, which is worthy of clinical application and promotion.

Acknowledgements

Not applicable.

Funding

No funding was received.

Availability of data and materials

The datasets used and/or analyzed during the present study are available from the corresponding author on reasonable request.

Authors' contributions

MX, WH and QL conceived and designed the study. MX, WH, SY and XW were responsible for the data collection and analysis. MX and QL were in charge of interpreting the data and drafting the manuscript. WH and SY made revisions from critical perspective for important intellectual content. The final version was read and approved by all authors.

Ethics approval and consent to participate

The study was approved by the Ethics Committee of First People's Hospital of Fuzhou (Fuzhou, China). Patients who participated in this research had complete clinical data. The signed informed consents were obtained from the patients or the guardians.

Patient consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

References

1 

Schulz-Drost S, Oppel P, Grupp S, Krinner S, Langenbach A, Lefering R and Mauerer A: Bony injuries of the thoracic cage in multiple trauma: Incidence, concomitant injuries, course and outcome. Unfallchirurg. 119:1023–1030. 2016.(In German). View Article : Google Scholar : PubMed/NCBI

2 

Coughlin TA, Ng JW, Rollins KE, Forward DP and Ollivere BJ: Management of rib fractures in traumatic flail chest: A meta-analysis of randomised controlled trials. Bone Joint J 98-B. 1119–1125. 2016. View Article : Google Scholar

3 

de Campos JRM and White TW: Chest wall stabilization in trauma patients: Why, when, and how? J Thorac Dis. 10 (Suppl 8):S951–S962. 2018. View Article : Google Scholar : PubMed/NCBI

4 

Wetterau LM, Smith-Singares E, Bilfinger T, Vosswinkel J, Shapiro MJ and Dagum AB: Management of pulmonary hernia through a flail segment in closed thoracic trauma using open reduction, internal fixation and pectoralis major flap reconstruction: a case report. Can J Plast Surg. 19:145–147. 2011. View Article : Google Scholar : PubMed/NCBI

5 

Nickerson TP, Thiels CA, Kim BD, Zielinski MD, Jenkins DH and Schiller HJ: Outcomes of complete versus partial surgical stabilization of flail chest. World J Surg. 40:236–241. 2016. View Article : Google Scholar : PubMed/NCBI

6 

Marasco SF, Davies AR, Cooper J, Varma D, Bennett V, Nevill R, Lee G, Bailey M and Fitzgerald M: Prospective randomized controlled trial of operative rib fixation in traumatic flail chest. J Am Coll Surg. 216:924–932. 2013. View Article : Google Scholar : PubMed/NCBI

7 

Pieracci FM, Lin Y, Rodil M, Synder M, Herbert B, Tran DK, Stoval RT, Johnson JL, Biffl WL, Barnett CC, et al: A prospective, controlled clinical evaluation of surgical stabilization of severe rib fractures. J Trauma Acute Care Surg. 80:187–194. 2016. View Article : Google Scholar : PubMed/NCBI

8 

Dehghan N, de Mestral C, McKee MD, Schemitsch EH and Nathens A: Flail chest injuries: a review of outcomes and treatment practices from the National Trauma Data Bank. J Trauma Acute Care Surg. 76:462–468. 2014. View Article : Google Scholar : PubMed/NCBI

9 

Qiu M, Shi Z, Xiao J, Zhang X, Ling S and Ling H: Potential benefits of rib fracture fixation in patients with flail chest and multiple non-flail rib fractures. Indian J Surg. 78:458–463. 2016. View Article : Google Scholar : PubMed/NCBI

10 

Broadhurst J, Moorjani N and Ohri S: Traumatic fracture of nitinol thermoreactive sternal clips. Interact Cardiovasc Thorac Surg. 10:465–466. 2010. View Article : Google Scholar : PubMed/NCBI

11 

Billè A, Okiror L, Karenovics W and Routledge T: Experience with titanium devices for rib fixation and coverage of chest wall defects. Interact Cardiovasc Thorac Surg. 15:588–595. 2012. View Article : Google Scholar : PubMed/NCBI

12 

Boonstra AM, Schiphorst Preuper HR, Balk GA and Stewart RE: Cut-off points for mild, moderate, and severe pain on the visual analogue scale for pain in patients with chronic musculoskeletal pain. Pain. 155:2545–2550. 2014. View Article : Google Scholar : PubMed/NCBI

13 

Schulte K, Whitaker D and Attia R: In patients with acute flail chest does surgical rib fixation improve outcomes in terms of morbidity and mortality? Interact Cardiovasc Thorac Surg. 23:314–319. 2016. View Article : Google Scholar : PubMed/NCBI

14 

Schulz-Drost S, Grupp S, Pachowsky M, Oppel P, Krinner S, Mauerer A, Hennig FF and Langenbach A: Stabilization of flail chest injuries: minimized approach techniques to treat the core of instability. Eur J Trauma Emerg Surg. 43:169–178. 2017. View Article : Google Scholar : PubMed/NCBI

15 

Yang H, Tantai J and Zhao H: Clinical experience with titanium mesh in reconstruction of massive chest wall defects following oncological resection. J Thorac Dis. 7:1227–1234. 2015.PubMed/NCBI

16 

Oyetunji TA, Jackson HT, Obirieze AC, Moore D, Branche MJ, Greene WR, Cornwell EE III and Siram SM: Associated injuries in traumatic sternal fractures: A review of the National Trauma Data Bank. Am Surg. 79:702–705. 2013.PubMed/NCBI

17 

Schulz-Drost S, Krinner S, Langenbach A, Oppel P, Lefering R, Taylor D, Hennig FF and Mauerer A; TraumaRegister DGU, : Concomitant sternal fracture in flail chest: an analysis of 21,741 polytrauma patients from the TraumaRegister DGU®. Thorac Cardiovasc Surg. 65:551–559. 2017. View Article : Google Scholar : PubMed/NCBI

18 

Yan Z, Liang Y, Fang Y, Yao X, Ma K and Huang F: Biomechanical study of nickel-titanium three-dimensional memory alloy mesh and autologous bone in treatment of canine tibial plateau collapse fracture. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 32:722–725. 2018.(In Chinese). PubMed/NCBI

19 

Li H, Mao Y, Qu X, Zhao X, Dai K and Zhu Z: Nickel-titanium shape-memory sawtooth-arm embracing clamp for complex femoral revision hip arthroplasty. J Arthroplasty. 31:850–856. 2016. View Article : Google Scholar : PubMed/NCBI

20 

Wu WM, Yang Y, Gao ZL, Zhao TC and He WW: Which is better to multiple rib fractures, surgical treatment or conservative treatment? Int J Clin Exp Med. 8:7930–7936. 2015.PubMed/NCBI

21 

Schuurmans J, Goslings JC and Schepers T: Operative management versus non-operative management of rib fractures in flail chest injuries: A systematic review. Eur J Trauma Emerg Surg. 43:163–168. 2017. View Article : Google Scholar : PubMed/NCBI

22 

Leinicke JA, Elmore L, Freeman BD and Colditz GA: Operative management of rib fractures in the setting of flail chest: a systematic review and meta-analysis. Ann Surg. 258:914–921. 2013. View Article : Google Scholar : PubMed/NCBI

23 

Zhao X, Zhu ZA, Sun YH, Wang Y, Zhao J, Zhang YJ and Dai KR: Nickel-titanium shape-memory sawtooth-arm embracing fixator for periprosthetic femoral fractures. Int Orthop. 36:619–626. 2012. View Article : Google Scholar : PubMed/NCBI

24 

De Palma A, Sollitto F, Loizzi D, Di Gennaro F, Scarascia D, Carlucci A, Giudice G, Armenio A, Ludovico R and Loizzi M: Chest wall stabilization and reconstruction: short and long-term results 5 years after the introduction of a new titanium plates system. J Thorac Dis. 8:490–498. 2016. View Article : Google Scholar : PubMed/NCBI

25 

Zhang Y, Tang X, Xie H and Wang RL: Comparison of surgical fixation and nonsurgical management of flail chest and pulmonary contusion. Am J Emerg Med. 33:937–940. 2015. View Article : Google Scholar : PubMed/NCBI

Related Articles

Journal Cover

July-2019
Volume 18 Issue 1

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Xiong M, Hu W, Lou Q, Yin S and Wang X: Efficacy of nickel‑titanium memory alloy in the treatment of multiple rib fracture combined with sternal fracture. Exp Ther Med 18: 537-542, 2019
APA
Xiong, M., Hu, W., Lou, Q., Yin, S., & Wang, X. (2019). Efficacy of nickel‑titanium memory alloy in the treatment of multiple rib fracture combined with sternal fracture. Experimental and Therapeutic Medicine, 18, 537-542. https://doi.org/10.3892/etm.2019.7597
MLA
Xiong, M., Hu, W., Lou, Q., Yin, S., Wang, X."Efficacy of nickel‑titanium memory alloy in the treatment of multiple rib fracture combined with sternal fracture". Experimental and Therapeutic Medicine 18.1 (2019): 537-542.
Chicago
Xiong, M., Hu, W., Lou, Q., Yin, S., Wang, X."Efficacy of nickel‑titanium memory alloy in the treatment of multiple rib fracture combined with sternal fracture". Experimental and Therapeutic Medicine 18, no. 1 (2019): 537-542. https://doi.org/10.3892/etm.2019.7597