A new thin-type bronchoscope improves diagnostic accuracy of peripheral pulmonary carcinoma

  • Authors:
    • Akira Iyoda
    • Makoto Suzuki
    • Masako Chiyo
    • Yasumitsu Moriya
    • Kazuhiro Yasufuku
    • Shigetoshi Yoshida
    • Yasuo Sekine
    • Kiyoshi Shibuya
    • Toshihiko Iizasa
    • Yukio Saitoh
    • Kenzo Hiroshima
    • Masayuki Baba
    • Takehiko Fujisawa
  • View Affiliations

  • Published online on: March 1, 2003     https://doi.org/10.3892/or.10.2.387
  • Pages: 387-389
Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

We investigated the XBF-4B40 (4B40) thin bronchoscope, which has a 4.0-mm outer diameter and a 2.0-mm biopsy channel, and studied its impact on the diagnosis of lung carcinoma. We analyzed 30 peripheral lung carcinoma cases by performing bronchoscopic examination using the 4B40 and the type 200 videoscope and recorded the most distal bronchus level reached. In addition, transbronchial aspiration biopsy, forceps biopsy, or brushing was performed, and the diagnosis accuracy between the two instruments was determined. The mean of the most distal bronchus reached by the 4B40 and the type 200 videoscope was the 4.5th and the 3rd, respectively. The 4B40 reached significantly further into the distal bronchus than the type 200 videoscope (p<0.0001). Accuracy for lesions detected in the right segment 1 or left segment 1+2 using the 4B40 and the type 200 videoscope was significantly different (p<0.0001) at 90.0 and 0%, respectively. The new type of bronchoscope, XBF-4B40, is useful for peripheral pulmonary lesion diagnosis with diagnosis accuracy improvements in the right segment 1 or the left segment 1+2.

Related Articles

Journal Cover

March-April 2003
Volume 10 Issue 2

Print ISSN: 1021-335X
Online ISSN:1791-2431

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Iyoda A, Suzuki M, Chiyo M, Moriya Y, Yasufuku K, Yoshida S, Sekine Y, Shibuya K, Iizasa T, Saitoh Y, Saitoh Y, et al: A new thin-type bronchoscope improves diagnostic accuracy of peripheral pulmonary carcinoma. Oncol Rep 10: 387-389, 2003
APA
Iyoda, A., Suzuki, M., Chiyo, M., Moriya, Y., Yasufuku, K., Yoshida, S. ... Fujisawa, T. (2003). A new thin-type bronchoscope improves diagnostic accuracy of peripheral pulmonary carcinoma. Oncology Reports, 10, 387-389. https://doi.org/10.3892/or.10.2.387
MLA
Iyoda, A., Suzuki, M., Chiyo, M., Moriya, Y., Yasufuku, K., Yoshida, S., Sekine, Y., Shibuya, K., Iizasa, T., Saitoh, Y., Hiroshima, K., Baba, M., Fujisawa, T."A new thin-type bronchoscope improves diagnostic accuracy of peripheral pulmonary carcinoma". Oncology Reports 10.2 (2003): 387-389.
Chicago
Iyoda, A., Suzuki, M., Chiyo, M., Moriya, Y., Yasufuku, K., Yoshida, S., Sekine, Y., Shibuya, K., Iizasa, T., Saitoh, Y., Hiroshima, K., Baba, M., Fujisawa, T."A new thin-type bronchoscope improves diagnostic accuracy of peripheral pulmonary carcinoma". Oncology Reports 10, no. 2 (2003): 387-389. https://doi.org/10.3892/or.10.2.387