Open Access

Impact of vitamin E-blended UHMWPE wear particles on the osseous microenvironment in polyethylene particle-induced osteolysis

  • Authors:
    • Carl Neuerburg
    • Theresa Loer
    • Lena Mittlmeier
    • Christina Polan
    • Zsuzsanna Farkas
    • Lesca Miriam Holdt
    • Sandra Utzschneider
    • Jens Schwiesau
    • Thomas M. Grupp
    • Wolfgang Böcker
    • Attila Aszodi
    • Christian Wedemeyer
    • Christian Kammerlander
  • View Affiliations

  • Published online on: October 18, 2016     https://doi.org/10.3892/ijmm.2016.2780
  • Pages: 1652-1660
  • Copyright: © Neuerburg et al. This is an open access article distributed under the terms of Creative Commons Attribution License.

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

Aseptic loosening mediated by wear particle-induced osteolysis (PIO) remains the major cause of implant loosening in endoprosthetic surgery. The development of new vitamin E (α-tocopherol)-blended ultra-high molecular weight polyethylene (VE-UHMWPE) with increased oxidation resistance and improved mechanical properties has raised hopes. Furthermore, regenerative approaches may be opened, as vitamin E supplementation has shown neuroprotective characteristics mediated via calcitonin gene-related peptide (CGRP), which is known to affect bone remodeling in PIO. Therefore, the present study aimed to further clarify the impact of VE-UHMWPE wear particles on the osseous microenvironment and to identify the potential modulatory pathways involved. Using an established murine calvaria model, mice were subjected to sham operation (SHAM group), or treated with UHMWPE or VE-UHMWPE particles for different experimental durations (7, 14 and 28 days; n=6/group). Morphometric analysis by micro-computed tomography detected significant (p<0.01) and comparable signs of PIO in all particle-treated groups, whereas markers of inflammation [tumor necrosis factor (TNF)-α/tartrate resistant acid phosphatase (TRAP) staining] and bone remodeling [Dickkopf-related protein 1 (DKK-1)/osteoprotegerin (OPG)] were most affected in the early stages following surgery. Taking the present data into account, VE-UHMWPE appears to have a promising biocompatibility and increased ageing resistance. According to the α-CGRP serum levels and immunohistochemistry, the impact of vitamin E on neuropeptidergic signaling and its chance for regenerative approaches requires further investigation.

Introduction

Endoprosthetic surgery in orthopedic and trauma patients is known to be one of the most successful reconstructive approaches, yet wear particle-induced osteolysis (PIO)-mediated by ultrahigh molecular weight polyethylene (UHMWPE) particles remains the major cause of implant loosening (13). Depending on the composition of the bearing couple, macrophages phagocytose released wear particles, which leads to an aseptic inflammatory response and subsequently induces osteolysis in the bone-implant interface (46). In order to face the problem of PIO, different approaches have been introduced.

In the field of biotribology, major improvements of endoprosthetic components have been presented in the past as an attempt to reduce wear and osteolysis. Thus, the development of new implant designs, materials, sterilisation techniques, oxidation resistance and articulating surface treatments have contributed to a reduction of wear, delamination and structural fatigue (7). As shown in hip and knee simulator studies, the development of improved inserts from conventional UHMWPE towards highly cross-linked UHMWPE is associated with a significant reduction of wear, while clinical investigations have observed reduced osteolysis (8,9).

The incorporation of vitamin E (α-tocopherol) into UHMWPE (VE-UHMWPE) either by diffusion following irradiation or blending followed by irradiation is a novel modification made in an aim to increase oxidation resistance and improve the mechanical properties of UHMWPE (10,11). As described previously, vitamin E has a positive impact in the process of ageing of UHMWPE which is related to a chemical reaction cascade between the macromolecules and oxygen. Irradiation processes from sterilisation or crosslinking generate free bonds (radicals) on the molecules which react with oxygen. One possible outcome of these reaction cascades is chain scission of the macromolecules, leading to mechanical property degradation. Vitamin E can donate hydrogen to react with the free bonds and interrupt this reaction cascade (12).

In a recent study, vitamin E supplementation was shown to have neuroprotective characteristics mediated via calcitonin gene-related peptide (CGRP) nerve fibers which can be of interest (13). Neuropeptides, such as α-CGRP have also been detected in the synovial fluid and periarticular tissue of loosened implants which strengthens the impact of the local neurogenic environment in the process of osteolysis and may open new regenerative therapy approaches (14,15). α-CGRP belongs to the calcitonin (CT) peptide family which is a generated analog to calcitonin by alternative splicing of the CALCA gene (16). Previous experiments using knockout mouse models with isolated or combined deficiency of CT/α-CGRP have provided further insight on the impact of the CT family peptides, whereas α-CGRP turned out to play an important role in the process of UHMWPE particle induced osteolysis (1719).

Therefore, the aim of the present study was to further clarify the impact of VE-UHMWPE wear particles on the osseous microenvironment of an established murine calvaria model and to identify the potential modulatory pathways.

Materials and methods

Animals

All experiments were performed and registered in accordance to the local authorities (Reference nos. 55.2-1-54-2532-232-2013) similar to the NIH guidelines for the care and use of laboratory animals (NIH Publication #85-23 Rev. 1985). As described previously, a murine calvaria model of UHMWPE particle-induced osteolysis was established using 54 male C57BL/6 mice provided by Charles River Laboratories, Inc. (Sulzfeld, Germany) (17,18). The animals were delivered at the age of 10 weeks and surgery was performed at the age of 12 weeks. The mice were divided into 3 groups as follows: one group was subjected to sham operation (SHAM group), the animals in the second group were treated with UHMWPE particles and the animals in the third group were treated with vitamin E-blended UHMWPE (VE-UHMWPE) particles. Furthermore, the animals were divided into subgroups according to the different durations of the experimental duration (7, 14 and 28 days). Thus, each group consisted of 6 mice. During the experimental period, food (V 1534-300; Ssniff Spezialdiäten GmbH, Soest, Germany) and water was supplied ad libitum. The animals were kept under specific pathogen-free (SPF) conditions. Post-operative analgesia was achieved using metamizole dissolved in the animals' drinking water (1.2 mg/ml). The animals were sacrificed at the end of the experimental duration, depending on the group.

Particles

The treated mice in the second group received conventional UHWMPE particles, whereas the animals in the third group received crosslinked VE-UHMWPE particles obtained from Aesculap (Tuttlingen, Germany) and generated as previously described (20). The equivalent circle diameter (ECD) of the UHMWPE particles [detected according to ASTM F 1877 (21)] was 1 μm, whereas 90% of the particles had a size <2 μm. Testing for cytotoxicity and endotoxin purity was performed according to the United States Pharmacopeial Convention (USP) given an endotoxin level <20.0 USP endotoxins per device and no cytotoxic reactivity.

Surgical procedure

All mice were anaesthetised by an intraperitoneal injection of fentanyl [0.05 mg/kg body weight (BW)], midazolam (5 mg/kg BW) and medetomidine (0.5 mg/kg BW). After shaving the head and sterile draping, a 1 cm skin incision over the calvarian sagittal midline suture was made and a 1×1 cm area of the periosteum was exposed and left intact as described previously (19). According to the experimental design, the animals in group A were subjected to sham operation only (SHAM group), the animals in group B received ~30 μl (2×108 particles/1,000 μl) of dried UHMWPE particles implanted periostally, and the animals in group C received an equivalent amount of VE-UHMWPE wear particles. The incision was closed using a 4-0 Ethilon skin suture (Ethicon, Sommerville, NJ, USA). The animals were sacrificed in a CO2 chamber following an experimental period of 7, 14 or 28 days according to their group.

Micro-computed tomography (μ-CT)

Microstructural differences of the different calvaria were assessed using high-resolution μ-CT (SkyScan 1072; SkyScan, Aartselaar, Belgium). Following sacrifice, the mouse skulls were separated using a sharp cutter at the neck for decapitation and fixed in 4% paraformaldehyde for 24 h and stored in 70% of ethanol thereafter. During scanning, the skulls were placed in a tightly fitting rigid plastic tube inside the scanner's chamber to avoid artifacts. With a resolution set at 19 μm at a source voltage of 80 kV and 100 μA, scanning was performed with rotation of the specimens in equiangular steps of 0.9°. Three-dimensional images were computed using the program Cone-beam Reconstruction (SkyScan). Quantitative analysis was performed using CT Analyser (CTAn; SkyScan) with a fixed volume of interest (VOI) having set a rectangular region of interest (ROI) of 4×4 mm centering the midline suture in the 2D-reconstructed cross-sectional slices. Within the VOI, the parameters of the osseous micro-architecture (BV/TV) were obtained as previously described (22). Three-dimensional images of the calvaria were generated using CT Vol (SkyScan).

Histological analysis

After μ-CT analysis, the decapitated skulls were prepared for histological processing; therefore, the calvaria were removed as an elliptical plate of bone defined by the foramen magnum, auditory canals and orbits. The scalp was kept in order to protect the calvaria in the operated area. The samples were then dehydrated in a graded alcohol series and embedded in a plastic embedding system based on methyl meth-acrylate (MMA) 'Technovit-9100' (Heraeus-Kulzer, Wehrheim, Germany). Following complete polymerization, the samples were cut using a 'charly' diamond saw (Walter Messner GmbH, Norderstedt, Germany) in the coronar plane of the calvaria. Of these samples, 5-μm-thick slices were cut using a Reichert-Jung rotary microtome (Reichert-Jung, Nussloch, Germany).

Masson-Goldner trichrome and toluidine blue staining were performed (Carl Roth GmbH, Karlsruhe, Germany) according to standard protocols. Tartrate resistant acid phosphatase (TRAP) staining was completed with a Napthol AS-BI phosphoric acid solution (N-2250; Sigma-Aldrich Chemie GmbH, Munich, Germany) on randomly selected slices from each group. Osteoclasts were detected in a set field of view following digital photography at a magnification of ×10 with the midline suture in its center (Axio Observer Z.1 AX10, connected to ZEN Imaging Software; Carl Zeiss Microscopy GmbH, Jena, Germany). Immunohistochemistry was performed using canine anti-mouse monoclonal tumor necrosis factor (TNF)-α-antibodies (Cat. no. 17590-1-AP; Acris Antibodies GmbH, Herford, Germany) in a first step conjugated with anti-canine peroxidase polymer in a second step for 30 min (Medac GmbH, Wedel, Germany). Color development was performed using the chromogen Bright DAB substrate kit (Immunologic, Duiven, The Netherlands) for 10 min. Counterstaining was performed with Mayer's hemalum solution for 5 min (Leica, Wetzlar, Germany). For α-CGRP antibody staining, canine anti-mouse polyclonal antibodies were used for 30 min (Cat. no. A78-128; Antibodies-online GmbH, Aachen, Germany) conjugated with anti-canine peroxidase polymer in a second step as stated above (Cat. no. 414141F; Medac GmbH). Similarly, counter-staining was performed with Mayer's hemalum solution (Leica). Dehydration was performed using a graded alcohol series. To rule out a potential cross-reactivity of the secondary antibody (α-CGRP/TNF-α) negative controls were generated with a dilution medium. Similarly, a positive control was prepared for each antibody using spleen samples of mouse cadavers.

Serum analyses

To rule out bone metabolic disorders, retro-orbital blood collection was performed at the beginning of the experimental period and calcium, phosphate and alkaline phosphatase levels were quantified. Prior to sacrifice, additional blood samples were taken via puncture of the vena cava. The serum samples were centrifuged at 8,000 × g for 10 min, aliquoted and frozen at −70°C.

Biomarker analysis was performed according to the manufacturer's instructions. Thus, serum α-CGRP levels were detected using a specific enzyme-linked immunosorbent assay (ELISA) kit provided by MyBioSource Inc. (MBS 721907; San Diego, CA, USA). As a marker of bone resorption, Dickkopf-1 (DKK-1) levels were detected using a DKK-1 Quantikine ELISA kit (R&D Systems, Minneapolis, MN, USA). The serum levels of osteoprotegerin (OPG), which is a marker of bone formation, were detected using a TNFRSF11B Quantikine ELISA kit (R&D Systems, Minneapolis, MN, USA).

Statistical analysis

Data are reported as the means ± standard deviation (SD). Normally distributed results were analysed by one-way analysis of variance (ANOVA) to identify global significant differences between groups, followed by post-hoc analysis via Tukey's test or Games-Howell test. In the case of significant variance of the normal distribution, non-parametric tests were applied using the method of Kruskal-Wallis. For statistical analysis, SPSS 22 (IBM Germany GmbH, Ehningen, Germany) was used and the level of significance was set at p<0.05. Graphics were created with GraphPad Prism 5.0 (GraphPad Software, Inc., La Jolla, CA, USA).

Results

Apart from 2 mice that suffered cardiovascular arrest under anesthesia, all animals tolerated the surgery and the experimental duration well.

μ-CT

Comparison of the calvarias' histomorphometry within the mice in the SHAM group revealed no relevant differences in bone volume density (BV/TV) between the different experimental duration times of 7, 14 or 28 days (Fig. 1). The intragroup comparison in the UHMWPE-treated mice revealed the smallest BV/TV in the mice within the 7-day experimental duration group, whereas there was a trend towards an increase in BV/TV when comparing the UHMWPE-treated mice at 7 and 14 days (p=0.101) and a significant increase in BV/TV in mice treated with the UHMWPE particles for 28 days compared to the animals within the 7-day experimental duration group (p<0.001). Similarly, the animals treated with the VE-UHMWPE particles (VE-UHMWPE) showed the lowest BV/TV in mice observed at 7 days, whereas there was a trend indicating an increase in BV/TV when comparing the mice treated for 7 days with those treated for 14 days (p=0.617), and a comparison of the animals treated with the VE-UHMWPE particles for 7 days with those treated for 28 days showed a significant increase in BV/TV (p<0.001).

Intergroup comparisons of BV/TV (Fig. 1) revealed a significantly reduced BV/TV in the mice treated with either the UHMWPE or VE-UHMWPE particles for 7 days compared to the mice in the SHAM group (p<0.001). No significant difference in BV/TV was observed when comparing the UHMWPE particle- with the VE-UHMWPE particle- treated mice at 7 days (p=0.960). At 14 days, there was still a reduction in BV/TV in the UHMWPE particle-treated mice (p=0.227) and VE-UHMWPE particle-treated mice (p=0.008) compared to the mice in the SHAM group. Whereas after a period of 28 days, the UHMWPE or VE-UHMWPE particle-treated mice showed a significant increase in BV/TV compared to the mice in the SHAM group (vs. UHMWPE, p=0.007; vs. VE-UHMWPE, p=0.018).

Inflammation and osteoclast activity

Immunohistochemistry revealed an increased TNF-α concentration in all mice in the 7-day experimental duration group compared those in the 28-day experimental duration group. TNF-α antibody staining was most intense at the surface of the calvaria in the area of the midline-suture, and there were no distinct inter- or intra-differences observed in a comparison of either the animals in the SHAM group or the particle treated animals (Fig. 2).

Similar to the TNF-α immunoreactivity, there were considerably more osteoclasts detected by TRAP staining (Fig. 3B) in all animals either in the SHAM group, or those treated with the UHMWPE or VE-UHMWPE particles at 7 days compared to the animals treated at 28 days (Fig. 3C). Intragroup comparison revealed a clear reduction in TRAP-positive cells after 14 days in the mice in the SHAM group and the UHMWPE particle-treated mice compared to their corresponding groups at 7 days, whereas a clear reduction in TRAP-positive cells in the VE-UHMWPE particle-treated mice was first observed after an experimental time of 28 days, although the SD was relatively large.

Histological analysis of the soft tissues surrounding the midline suture was associated with an increased inflammatory response which was most obvious in the mice in the 7-day experimental duration group, as indicated by the granulomatous tissue on Masson-Goldner-stained sections (Fig. 3A).

α-CGRP-mediated local neurogenic microenvironment

Biomarker analysis of the serum revealed an increase in the α-CGRP levels in all groups given a longer experimental time (Fig. 4A). In the UHMWPE and VE-UHMWPE particle-treated mice, the detected α-CGRP levels were significantly higher at 28 days compared to those at 14 days (p=0.036 and p<0.001). Intergroup comparisons only revealed significantly higher α-CGRP levels in the mice treated with the VE-UHMWPE particles for 28 days compared to the corresponding controls (SHAM group; p=0.009).

According to immunohistochemistry, however, α-CGRP antibody staining revealed a more distinct α-CGRP concentration in the UHMWPE and VE-UHMWPE particle-treated groups after a period of 14 days compared to their counterparts with an experimental time of 7 days (Fig. 4B).

Biochemical markers of bone turnover

Bone metabolic disorders were excluded at the beginning of the experimental duration time by the detection of calcium, phosphate and alkaline phosphatase levels. Following dilution with saline in a ratio of 1:2, the mean calcium level detected in serum at the beginning of the experimental time was 0.74+0.08 mmol/l, the mean phosphate level was 2.1+0.3 mg/dl and the mean alkaline phosphatase level was 30.08+4.7 U/l. There were no relevant inter- or intragroup differences observed in any of the animals at the beginning of the experimental duration time (data not shown).

At the end of the experimental time, marker analysis for bone resorption revealed significantly elevated DKK-1 levels in the mice in the SHAM group and the UHMWPE particle-treated animals at the experimental time of 7 days compared to their corresponding groups at 14 days (p<0.05), though no significant differences were observed in a similar comparison of the VE-UHMWPE particle-treated mice (p=0,999; Fig. 5A). Generally, the DKK-1 levels were lowest in all groups of mice at the experimental time of 14 days followed by a minor increase in DKK-1 levels in the animals treated at 28 days. Intergroup analysis, however, revealed no significant differences between any of the groups.

Similar to the DKK-1 levels, the levels of the marker of bone formation, OPG, were higher in all animals treated at 7 days compared to the experimental time of 14 days (Fig. 5B). Although this difference was only significant in the UHMWPE and VE-UHMWPE-particle treated mice (p=0.005), there were no significant differences between the different groups. In the treated animals at 28 days, there was a trend towards increased OPG levels in all groups, yet there was not statistically significant difference.

Discussion

The biotribological performance of implants in endoprosthetic surgery is of superior importance as it contributes to the stability and longevity of implant anchorage. Therefore, the present study investigated the impact of VE-UHMWPE wear particles on the osseous microenvironment compared to UHMWPE wear particles.

In both the UHMWPE and VE-UHMWPE particle-treated groups, significant signs of particle-induced osteolysis were observed in the animals at 7 and 14 days compared to their corresponding controls (SHAM group). Of note, in the treated mice at 28 days, an increase in BV/TV was observed in both the UHMWPE and VE-UHMWPE particle-treated mice compared to the mice in the SHAM group, which could be attributed by a reactive osteoinduction following an increased inflammation in the early post-operative phase. In the present study, no significant differences in osteolysis were observed between the UHWMPE and VE-UHMWPE particle-treated mice, which is contradictory to the results reported by Bichara et al, who recently found a reduced osteolytic potential in VE-UHMWPE particle-treated mice compared to the controls (23). Another study on that topic published by Huang et al within this year also found similar signs of osteolysis between mice treated with vitamin E-containing particles and conventional UHMWPE wear particles (24). However, both studies investigated a murine calvaria model at a distinct time-point (10/14 days). Furthermore, Bichara et al investigated very young animals at the age of 8 weeks, whereas Huang et al used wear particles generated from wearing simulators; thus, the observed effect is likely to differ from PIO as it is typically seen. The use of an established murine calvaria model with different experimental duration times and more detailed immunohistochemical investigations may provide further insight. Diverging results may be attributed to the size of particles implanted, as the particle size is known to have a significant impact on the extent of the biological reaction to wear debris (25). Wear particles in the phagocytosable range from 0.3 to 10 μm have been associated with the highest biological activity in in vitro studies (26). Studies on wear particles from retrieved human periprosthetic tissues and worn polyethylene surfaces are consistent with an average particle size in the range of 0.5 μm in diameter (27). However, the ECD of the wear particles used in the present study was similar to the size of particles used in the experiments conducted by Bichara et al and Huang et al. Apart from the particle size, differences in reactivity may also be associated with the composition of wear particles. Thus, Bichara et al and Huang et al used cross-linked UHMWPE particles in their control group, whereas conventional UHMWPE particles were used in the present study, while differences in reactivity of conventional vs. cross-linked UHMWPE particles remain a matter of discussion (28). In addition, the amount of wear particles may have attributed to the extent of osteolysis observed in the UHMWPE and VE-UHMWPE particle-treated mice in the present study compared to the mice in the SHAM group. Thus, as an attempt to provoke a severe inflammatory response and to determine the osteolytic potential of UHMWPE and VE-UHMWPE particles, an extremely high concentration of particles was chosen in the present study, which was adapted to the amount of wear used in previous experiments by our group (18,19). Huang et al treated the calvaria with 1 mg of wear particles, Bichara et al chose a concentration of 3 mg, whereas a 30- to 10-fold higher particle concentration was chosen in the present study. In hip arthroplasty, a 28-mm head with linear wear of 0.05 mm/y corresponds to a volumetric wear rate of 30 mm3/y (27).

Therefore, a closer investigation of the osseous microenvironment and bone turnover may provide further insight into the biological activity of VE-UHMWPE wear particles in comparison to UHMWPE particles. As expected, the inflammatory response was pronounced in the early post-operative stage given the higher concentrations of TNF-α observed in all mice at day 7, accompanied by an increased number of osteoclasts. In the particle-treated mice, these appearances were associated with significant osteolysis, as indicated by a reduction in BV/TV. These data are supported by prior investigations on the inflammatory response of polyethylene particles. For example, Takahashi et al, using a luminescence murine calvaria model in NF-κB/luciferase transgenic mice, found that the level of luminescence was maximal at day 7 associated with a significant correlation with pro-inflammatory mediator mRNAs and bone resorption parameters (29). As TNF-α has been shown to be one of the key factors in the process of osteoclastogenesis, the use of anti-TNF agents may be a useful regenerative approach in the treatment of joint inflammation related to osteolysis (30). Whereas investigations on the biological reaction to wear particles have found a minor inflammatory response of ceramic wear particles compared to polyethylene wear particles (31), the present study revealed no potential differences in the inflammatory response in between UHMWPE and VE-UHMWPE wear particles.

Given the findings of α-CGRP in the synovial fluid and periarticular tissue of loosened implants and the modulatory effect of vitamin E on CGRP-based neuropeptides known from different experimental setups, further investigations in the present study aimed to identify the impact of VE-UHMWPE wear particles on the local neurogenic environment. Thus, biomarker analysis of serum α-CGRP showed a continuous increase in α-CGRP levels throughout the experimental duration time in all groups (SHAM, UHMWPE and VE-UHMWPE) and significantly higher α-CGRP levels in the VE-UHMWPE particle-treated mice at the experimental time of 28 days, whereas minor α-CGRP antibody concentrations were detectable for the first time via immunohistochemistry at day 14 in the UHMWPE and VE-UHMWPE particle-treated mice. Recent investigations by our group on haploinsufficient calcitonin receptor knockout mice identified that regenerative strategies in the aseptic loosening of endoprosthetic implants should focus on the impact of α-CGRP-mediated signalling, although previous results have to be considered (18). Thus, experiments on α-CGRP-deficient mice have demonstrated reduced PIO associated with decreased RANKL mRNA levels compared to wild-type controls, presuming a catabolic effect of α-CGRP in particle induced osteolysis (19). On the contrary, in vitro analysis observed a time-dependent inhibitory effect of α-CGRP on the secretion of osteolysis-associated pro-inflammatory cytokines such as TNF-α (32). Therefore, the observed increase in α-CGRP levels found in the present study in the VE-UHMWPE particle-treated mice after a period of 28 days compared to the sham-operated controls has to be interpreted with caution. Although there is evidence, that α-CGRP has a modulatory effect on the production of pro-inflammatory cytokines, its impact is not yet fully understood and there are limited data on the interaction between vitamin E and CGRP. As stated above, Tashima et al found that vitamin E supplementation provided a neuroprotective effect associated with a reduction in number of CGRP nerve fiber varicosities in the jejunum in experimental diabetes (13), although transmission of this interaction to the process of PIO involved uncertainties. Furthermore, the authors did not specify whether they detected α-CGRP or β-CGRP nerve fibres, which differ from each other.

The investigation of bone turnover may therefore be an opportunity to further identify the impact of VE-UHMWPE particles in the process of PIO. It is well known that osteoclast and osteoblast activities in PIO are mediated by various inflammatory cytokines released from macrophages following the phagocytosis of wear particles (33). Therefore, differences in markers of bone formation and bone resorption would be expected if there were differences in the inflammatory response between UHMWPE and VE-UHMWPE wear particles. In the present study, significantly higher levels of DKK-1, a marker of bone resorption, were found in all mice after a period of 7 days compared to serum levels detected after a period of 14 days. Serum analysis similarly revealed significantly higher levels of OPG, a marker of bone formation, in particle-treated mice after a period of 7 days compared to the controls at 14 days. Taken together, no significant differences with regards to the inflammatory potential were observed between the UHMWPE und VE-UHMWPE particle-treated mice. These data are in accordance with previous in vitro testing comparing the biocompatibility of UHMWPE and vitamin E (α-tocopherol)-stabilised UHMWPE tablets, in which similar proliferation rates were found in both polyethylene samples with no evidence of cytotoxicity (34).

In conclusion, the investigation of a very high concentration of VE-UHMWPE wear particles in an established murine calvaria model revealed a comparable extent of PIO as observed in UHMWPE wear particles. Only minor differences between the VE-UHMWPE particle- compared to the UHMWPE particle-treated mice were found with regards to an activation of inflammatory cytokines and osteoclasts, which was most distinct in the early stages after surgery. The impact of increased α-CGRP levels observed in the mice treated with the VE-UHMWPE particles at 28 days and the influence of vitamin E on CGRP requires further investigation. However, as there were no differences in bone turnover between UHMWPE and VE-UHMWPE particle-treated mice, vitamin E-blended UHMWPE particles appear to have a reasonable biocompatibility. Taking the improved data on the tribologic and mechanical properties associated with a reduction of released wear particles into account, and given the increased ageing resistance of vitamin E-blended UHMWPE particles, the stabilization of polyethylene-bearing couples with vitamin E appears to be a promising approach (12,35). Further investigations on different concentrations of VE-UHMWPE wear particles and the identification of potential regenerative strategies remain of interest to reduce the extent of wear particle induced osteolysis in future.

Study limitations

There are some constraints of the experimental setup of this study, thus a very high concentration of wear particles was chosen as an attempt to provoke an inflammatory response which does not resemble the amount of wear occurring in humans. Furthermore, animals chosen for the present study were at the age of 12 weeks, as these wild-type mice are used very frequently this provides better comparison with other data, yet it has been shown that there are potential differences in bone metabolism of younger and aged mice (36). Also there may have been compensatory effects influencing the inflammatory response observed in the present model of particle induced osteolysis which could have been induced by other cytokines or peptide hormones that have not been detected.

Acknowledgments

The authors wish to thank Dr. A. Riedasch for support during the experimental time in the laboratory of animal science. Also many thanks to Mr. W. Wilfert at the Institute of Laboratory Medicine for the implementation of biomarker analysis. This study was supported by a research grant provided by the Friedrich-Baur-Foundation (FBS). The authors J. Schwiesau and T.M. Grupp are employes of the Aesculap AG.

References

1 

Garellick G, Kärrholm J, Rogmark C, Rolfson O and Herberts P: Swedish Hip Arthroplasty Register, Annual Report 2011. Gothenburg, Sweden: 2012, ISBN: 978-91-980507-1-4

2 

Jiang J, Yang CH, Lin Q, Yun XD and Xia YY: Does arthroplasty provide better outcomes than internal fixation a mid- and long-term followup? A meta-analysis. Clin Orthop Relat Res. 473:2672–2679. 2015. View Article : Google Scholar : PubMed/NCBI

3 

Learmonth ID, Young C and Rorabeck C: The operation of the century: Total hip replacement. Lancet. 370:1508–1519. 2007. View Article : Google Scholar : PubMed/NCBI

4 

Drees P, Eckardt A, Gay RE, Gay S and Huber LC: Molecular pathways in aseptic loosening of orthopaedic endoprosthesis. Biomed Tech (Berl). 53:93–103. 2008.In German. View Article : Google Scholar

5 

Rubash HE, Sinha RK, Shanbhag AS and Kim SY: Pathogenesis of bone loss after total hip arthroplasty. Orthop Clin North Am. 29:173–186. 1998. View Article : Google Scholar : PubMed/NCBI

6 

Schmalzried TP, Jasty M and Harris WH: Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space. J Bone Joint Surg Am. 74:849–863. 1992. View Article : Google Scholar : PubMed/NCBI

7 

Grupp TM, Utzschneider S and Wimmer MA: Biotribology in knee arthroplasty. BioMed Res Int. 2015:6189742015. View Article : Google Scholar : PubMed/NCBI

8 

Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M and Harris WH: A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty. 16:149–160. 2001. View Article : Google Scholar : PubMed/NCBI

9 

Thomas GE, Simpson DJ, Mehmood S, Taylor A, McLardy-Smith P, Gill HS, Murray DW and Glyn-Jones S: The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: A double-blind, randomized controlled trial using radiostereometric analysis. J Bone Joint Surg Am. 93:716–722. 2011. View Article : Google Scholar : PubMed/NCBI

10 

Oral E, Godleski Beckos C, Malhi AS and Muratoglu OK: The effects of high dose irradiation on the cross-linking of vitamin E-blended ultrahigh molecular weight polyethylene. Biomaterials. 29:3557–3560. 2008. View Article : Google Scholar : PubMed/NCBI

11 

Oral E, Wannomae KK, Rowell SL and Muratoglu OK: Diffusion of vitamin E in ultra-high molecular weight polyethylene. Biomaterials. 28:5225–5237. 2007. View Article : Google Scholar : PubMed/NCBI

12 

Schwiesau J, Fritz B, Kutzner I, Bergmann G and Grupp TM: CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities. BioMed Res Int. 2014:5673742014. View Article : Google Scholar : PubMed/NCBI

13 

Tashima CM, Hermes-Uliana C, Perles JV, de Miranda Neto MH and Zanoni JN: Vitamins C and E (ascorbate/α-tocopherol) provide synergistic neuroprotection in the jejunum in experimental diabetes. Pathophysiology. 22:241–248. 2015. View Article : Google Scholar : PubMed/NCBI

14 

Qian Y, Zeng BF, Zhang XL and Jiang Y: High levels of substance P and CGRP in pseudosynovial fluid from patients with aseptic loosening of their hip prosthesis. Acta Orthop. 79:342–345. 2008. View Article : Google Scholar : PubMed/NCBI

15 

Saxler G, Löer F, Skumavc M, Pförtner J and Hanesch U: Localization of SP- and CGRP-immunopositive nerve fibers in the hip joint of patients with painful osteoarthritis and of patients with painless failed total hip arthroplasties. Eur J Pain. 11:67–74. 2007. View Article : Google Scholar

16 

Schinke T, Liese S, Priemel M, Haberland M, Schilling AF, Catala-Lehnen P, Blicharski D, Rueger JM, Gagel RF, Emeson RB and Amling M: Decreased bone formation and osteopenia in mice lacking alpha-calcitonin gene-related peptide. J Bone Miner Res. 19:2049–2056. 2004. View Article : Google Scholar : PubMed/NCBI

17 

Kauther MD, Neuerburg C, Wefelnberg F, Bachmann HS, Schlepper R, Hilken G, Broecker-Preuss M, Grabellus F, Schilling AF, Jäger M and Wedemeyer C: RANKL-associated suppression of particle-induced osteolysis in an aged model of calcitonin and α-CGRP deficiency. Biomaterials. 34:2911–2919. 2013. View Article : Google Scholar : PubMed/NCBI

18 

Neuerburg C, Wedemeyer C, Goedel J, Schlepper R, Hilken G, Schwindenhammer B, Schilling AF, Jäger M and Kauther MD: The role of calcitonin receptor signalling in polyethylene particle-induced osteolysis. Acta Biomater. 14:125–132. 2015. View Article : Google Scholar

19 

Wedemeyer C, Neuerburg C, Pfeiffer A, Heckelei A, Bylski D, von Knoch F, Schinke T, Hilken G, Gosheger G, von Knoch M, et al: Polyethylene particle-induced bone resorption in alpha-calcitonin gene-related peptide-deficient mice. J Bone Miner Res. 22:1011–1019. 2007. View Article : Google Scholar : PubMed/NCBI

20 

Utzschneider S, Becker F, Grupp TM, Sievers B, Paulus A, Gottschalk O and Jansson V: Inflammatory response against different carbon fiber-reinforced PEEK wear particles compared with UHMWPE in vivo. Acta Biomater. 6:4296–4304. 2010. View Article : Google Scholar : PubMed/NCBI

21 

Standard Practice for Characterization of Particles. American Society for Testing and Materials; West Conshohocken: 2010

22 

Wedemeyer C, Xu J, Neuerburg C, Landgraeber S, Malyar NM, von Knoch F, Gosheger G, von Knoch M, Löer F and Saxler G: Particle-induced osteolysis in three-dimensional micro-computed tomography. Calcif Tissue Int. 81:394–402. 2007. View Article : Google Scholar : PubMed/NCBI

23 

Bichara DA, Malchau E, Sillesen NH, Cakmak S, Nielsen GP and Muratoglu OK: Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo. J Arthroplasty. 29(Suppl): 232–237. 2014. View Article : Google Scholar : PubMed/NCBI

24 

Huang CH, Lu YC, Chang TK, Hsiao IL, Su YC, Yeh ST, Fang HW and Huang CH: In vivo biological response to highly cross-linked and vitamin e-doped polyethylene - a particle-Induced osteolysis animal study. J Biomed Mater Res B Appl Biomater. 104:561–567. 2016. View Article : Google Scholar

25 

Gallo J, Slouf M and Goodman SB: The relationship of polyethylene wear to particle size, distribution, and number: A possible factor explaining the risk of osteolysis after hip arthroplasty. J Biomed Mater Res B Appl Biomater. 94:171–177. 2010.PubMed/NCBI

26 

Green TR, Fisher J, Stone M, Wroblewski BM and Ingham E: Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro. Biomaterials. 19:2297–2302. 1998. View Article : Google Scholar

27 

Bezwada HP, Nazarian D and Booth R: Acetabular wear in total hip arthroplasty. E-Medicine.com; pp. 1–15. 2004

28 

Catelas I, Wimmer MA and Utzschneider S: Polyethylene and metal wear particles: Characteristics and biological effects. Semin Immunopathol. 33:257–271. 2011. View Article : Google Scholar : PubMed/NCBI

29 

Takahashi K, Onodera S, Tohyama H, Kwon HJ, Honma K and Yasuda K: In vivo imaging of particle-induced inflammation and osteolysis in the calvariae of NFκB/luciferase transgenic mice. J Biomed Biotechnol. 2011:7270632011. View Article : Google Scholar

30 

Dong L, Wang R, Zhu YA, Wang C, Diao H, Zhang C, Zhao J and Zhang J: Antisense oligonucleotide targeting TNF-α can suppress Co-Cr-Mo particle-induced osteolysis. J Orthop Res. 26:1114–1120. 2008. View Article : Google Scholar : PubMed/NCBI

31 

Warashina H, Sakano S, Kitamura S, Yamauchi KI, Yamaguchi J, Ishiguro N and Hasegawa Y: Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria. Biomaterials. 24:3655–3661. 2003. View Article : Google Scholar : PubMed/NCBI

32 

Jablonski H, Kauther MD, Bachmann HS, Jager M and Wedemeyer C: Calcitonin gene-related peptide modulates the production of pro-inflammatory cytokines associated with periprosthetic osteolysis by THP-1 macrophage-like cells. Neuroimmunomodulation. 22:152–165. 2015. View Article : Google Scholar

33 

Landgraeber S, Jäger M, Jacobs JJ and Hallab NJ: The pathology of orthopedic implant failure is mediated by innate immune system cytokines. Mediators Inflamm. 2014:1851502014. View Article : Google Scholar : PubMed/NCBI

34 

Wolf C, Lederer K, Pfragner R, Schauenstein K, Ingolic E and Siegl V: Biocompatibility of ultra-high molecular weight polyethylene (UHMW-PE) stabilized with alpha-tocopherol used for joint endoprostheses assessed in vitro. J Mater Sci Mater Med. 18:1247–1252. 2007. View Article : Google Scholar : PubMed/NCBI

35 

Bracco P and Oral E: Vitamin E-stabilized UHMWPE for total joint implants: A review. Clin Orthop Relat Res. 469:2286–2293. 2011. View Article : Google Scholar :

36 

Langlois J, Zaoui A, Bichara DA, Nich C, Bensidhoum M, Petite H, Muratoglu OK and Hamadouche M: Biological reaction to polyethylene particles in a murine calvarial model is highly influenced by age. J Orthop Res. 34:574–580. 2016. View Article : Google Scholar

Related Articles

Journal Cover

December-2016
Volume 38 Issue 6

Print ISSN: 1107-3756
Online ISSN:1791-244X

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Neuerburg C, Loer T, Mittlmeier L, Polan C, Farkas Z, Holdt LM, Utzschneider S, Schwiesau J, Grupp TM, Böcker W, Böcker W, et al: Impact of vitamin E-blended UHMWPE wear particles on the osseous microenvironment in polyethylene particle-induced osteolysis. Int J Mol Med 38: 1652-1660, 2016
APA
Neuerburg, C., Loer, T., Mittlmeier, L., Polan, C., Farkas, Z., Holdt, L.M. ... Kammerlander, C. (2016). Impact of vitamin E-blended UHMWPE wear particles on the osseous microenvironment in polyethylene particle-induced osteolysis. International Journal of Molecular Medicine, 38, 1652-1660. https://doi.org/10.3892/ijmm.2016.2780
MLA
Neuerburg, C., Loer, T., Mittlmeier, L., Polan, C., Farkas, Z., Holdt, L. M., Utzschneider, S., Schwiesau, J., Grupp, T. M., Böcker, W., Aszodi, A., Wedemeyer, C., Kammerlander, C."Impact of vitamin E-blended UHMWPE wear particles on the osseous microenvironment in polyethylene particle-induced osteolysis". International Journal of Molecular Medicine 38.6 (2016): 1652-1660.
Chicago
Neuerburg, C., Loer, T., Mittlmeier, L., Polan, C., Farkas, Z., Holdt, L. M., Utzschneider, S., Schwiesau, J., Grupp, T. M., Böcker, W., Aszodi, A., Wedemeyer, C., Kammerlander, C."Impact of vitamin E-blended UHMWPE wear particles on the osseous microenvironment in polyethylene particle-induced osteolysis". International Journal of Molecular Medicine 38, no. 6 (2016): 1652-1660. https://doi.org/10.3892/ijmm.2016.2780