Open Access

Effects of anesthesia on conventional and speckle tracking echocardiographic parameters in a mouse model of pressure overload

  • Authors:
    • Guan Wang
    • Le Zhang
    • Anne Manyande
    • Ming Cao
    • Wei He
    • Xiaofen Wu
    • Jinli Wang
    • Cuntai Zhang
  • View Affiliations

  • Published online on: March 3, 2015     https://doi.org/10.3892/etm.2015.2331
  • Pages: 1679-1687
  • Copyright: © Wang et al. This is an open access article distributed under the terms of Creative Commons Attribution License.

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

Genetically‑modified mice are widely applied in cardiovascular studies as model organisms. Echocardiography is a key tool for evaluating cardiac and hemodynamic functions in mice. The present study aimed to examine the effects of isoflurane (ISF) on conventional and speckle tracking echocardiography (STE) parameters under healthy and pathological conditions using a murine model of pressure overload. In addition, the optimal dose of ISF in the process of echocardiographic measurement, with minimum cardiac contraction depression, was investigated. Conventional echocardiographic and STE examinations were performed on 38 adult C57BL/6 male mice. The mice were divided into the following three groups: The sham (n=15); mild thoracic aortic banding (TAB; n=15); and severe TAB (n=8) groups. ISF was administered under deep anesthesia (DA; 1‑2% ISF), light anesthesia (LA; 0.5‑1% ISF) and immediately prior to the mice waking up (awake; 0‑0.5% ISF). Conventional echocardiographic parameters were preserved within the sham and mild TAB groups (P>0.05 for each parameter) under LA and awake conditions. However, under DA conditions, the majority of these parameters were reduced compared with the LA and awake conditions (P<0.05). In the severe TAB group, conventional echocardiographic parameters remained constant under LA, DA and awake conditions. STE parameters in the groups remained similar between the LA and awake conditions, but were significantly reduced under DA conditions. Therefore, conventional echocardiography and STE may be performed using LA induced with low doses of ISF, under various pathological conditions without affecting cardiac function.
View Figures
View References

Related Articles

Journal Cover

May-2015
Volume 9 Issue 5

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Wang G, Zhang L, Manyande A, Cao M, He W, Wu X, Wang J and Zhang C: Effects of anesthesia on conventional and speckle tracking echocardiographic parameters in a mouse model of pressure overload. Exp Ther Med 9: 1679-1687, 2015
APA
Wang, G., Zhang, L., Manyande, A., Cao, M., He, W., Wu, X. ... Zhang, C. (2015). Effects of anesthesia on conventional and speckle tracking echocardiographic parameters in a mouse model of pressure overload. Experimental and Therapeutic Medicine, 9, 1679-1687. https://doi.org/10.3892/etm.2015.2331
MLA
Wang, G., Zhang, L., Manyande, A., Cao, M., He, W., Wu, X., Wang, J., Zhang, C."Effects of anesthesia on conventional and speckle tracking echocardiographic parameters in a mouse model of pressure overload". Experimental and Therapeutic Medicine 9.5 (2015): 1679-1687.
Chicago
Wang, G., Zhang, L., Manyande, A., Cao, M., He, W., Wu, X., Wang, J., Zhang, C."Effects of anesthesia on conventional and speckle tracking echocardiographic parameters in a mouse model of pressure overload". Experimental and Therapeutic Medicine 9, no. 5 (2015): 1679-1687. https://doi.org/10.3892/etm.2015.2331