Concordance of 24‑h intraocular pressure curve in patients with untreated unilateral primary open‑angle glaucoma

  • Authors:
    • Zhongjing Lin
    • Shouyue Huang
    • Ping Huang
    • Changwei Li
    • Zhenghua Chen
    • Yisheng Zhong
  • View Affiliations

  • Published online on: June 15, 2018     https://doi.org/10.3892/etm.2018.6315
  • Pages: 1461-1469
Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

The present study aimed to assess the concordance of 24‑h intraocular pressure (IOP) curves between glaucomatous and contralateral eyes for patients with untreated unilateral primary open‑angle glaucoma (POAG). A total of 32 patients with unilateral POAG and 32 age‑matched normal subjects were enrolled. The IOP measurements were performed every 2 h over a 24‑h period. The concordance of the 24‑h IOP curves was assessed via the correlation coefficient (r), intraclass correlation coefficient (ICC) and repeated‑measures analysis of variance (ANOVA). No significant difference was identified between all IOPs, as well as the mean, peak and trough IOP or IOP fluctuations of the paired eyes in the two groups. The strength of association of all IOPs was moderate in the glaucoma group (r, 0.752‑0.867) and the normal controls (r, 0.625‑0.873). IOP readings at each time‑point indicated a high agreement in the glaucoma group (ICC, 0.857‑0.929) and the normal controls (ICC, 0.768‑0.932). Repeated‑measures ANOVA indicated that the 24‑h IOP curves of the paired eyes had parallel profiles in the two study groups (P=0.837 and P=0.897, respectively). The glaucoma patients had significantly higher proportions of all IOPs displaying absolute differences of ≥2 and ≥3 mmHg (46.09 vs. 35.68%, P<0.001; 29.69 vs. 12.50%, P<0.001, respectively). In conclusion, the 24‑h IOP curves of the paired eyes had parallel profiles in unilateral glaucoma patients and normal subjects. However, unilateral glaucoma patients had a significantly larger proportion of IOP differences of ≥2 and ≥3 mmHg.

Introduction

Primary open-angle glaucoma (POAG) is a chronic optic neuropathy that is progressive and generally bilateral, but frequently asymmetric. It is estimated that ~80 million individuals aged 40-80 years will have developed POAG by 2040 (1). Although the precise pathogenesis remains to be elucidated, intraocular pressure (IOP) is considered to be the most significant risk factor contributing to the development and progression of the disease (2,3). As an assumption of symmetrical variation of IOP between the right eye and the left eye in healthy individuals was previously made (4), a significant interocular difference in IOP, also known as IOP asymmetry, has been recognized as an additional risk factor for glaucoma (5,6). A 1-mmHg increase in IOP asymmetry between a pair of eyes is correlated with a 17% increase in the risk for the development of POAG (7).

Previous studies have explored the concordance of IOP curves in glaucoma patients, only to obtain inconsistent results (810). However, in these studies, the enrolment criteria for the study populations of glaucoma patients were not strict, as there was no limitation regarding the degree of retinal nerve fiber layer (RNFL) defect or visual field defect. Therefore, whether asymmetric glaucomatous damage is attributed to asymmetric IOP curves remains elusive. A clinical evaluation of symmetry in unilateral glaucoma may be able to demonstrate this hypothesis. In addition, the IOP in an individual is not stable as expected, and fluctuation in IOP is a well-known phenomenon. It changes over short and long periods ranging from days to months (11,12). Therefore, repeated IOP measurements, particularly 24-h IOP readings, are an important factor to evaluate the clinical course.

In the present study, glaucoma patients who had RNFL defects and visual field defects in only one eye and a normal fellow eye on examination were selected, which allowed for better investigation of the association between the onset of glaucomatous changes and potential disturbances in IOP. The fellow eyes were compared to the corresponding glaucomatous eyes and the eyes of healthy control subjects to test for any evidence of asymmetry in 24-h IOP curves. To the best of our knowledge, the present study was the first to assess the concordance of 24-h IOP curves in patients with untreated unilateral glaucoma.

Materials and methods

Study population

In the present observational study, all of the participants who visited the Ophthalmology Clinic at Ruijin Hospital between May 2016 and May 2017 were considered.

POAG patients enrolled in the present study had to meet the following inclusion criteria: A typical glaucomatous optic disc abnormality (diffuse or localized thinning of the neuro-retinal rim, rim notching or inter-eye asymmetry of vertical cup-to-disc ratio >0.2), corresponding glaucomatous visual field loss and an open angle on gonioscopic examination (13). Unilateral POAG was defined as POAG patients with a characteristic RNFL defect (Fig. 1A and B) and corresponding visual field defect (Fig. 1C) in only one eye and the other eye appearing normal on ophthalmic examination. The eye with visual field defect was designated as the affected eye and the other eye was designated as the fellow eye. All participants were newly diagnosed POAG patients who had not received any previous anti-glaucoma treatments. The population of normal subjects, recruited from healthy individuals seeking physical examination in the outpatient department, was comprised of subjects without any evidence of RNFL defect and with normal visual field test results. IOP measurements were >21 mmHg on different days. Subjects with concomitant ocular diseases, severe systemic disease, previous ocular surgery or any medical treatment for glaucoma were excluded. Those whose central corneal thickness (CCT) measured >650 or <450 µm were also excluded from the study.

Ophthalmologic examination

All participants underwent a comprehensive ophthalmologic examination, including best-corrected visual acuity, slit-lamp examination, gonioscopy and fundus examination. CCT was measured three times using an ocular biometer (IOL Master; Carl Zeiss Meditec, Dublin, CA, USA), and the mean value of three consecutive readings within a range of 5 µm was calculated for each eye. A Humphrey Field Analyzer II (Carl Zeiss Meditec) was used for visual field examinations, with the Swedish Interactive Threshold Algorithm Fast strategy and the 30-2 test pattern (14). All participants had been subjected to at least two prior visual field tests. Visual fields were defined as normal if the Glaucoma Hemifield Test was within normal limits, and the pattern deviation plots indicated no sign of one or more clusters of three or more neighboring test points with a sensitivity loss of >5 dB, or two adjacent test points with a sensitivity loss of >10 dB. Two qualifying visual field tests were performed to confirm the glaucomatous visual field loss. Furthermore, all of the participants were tested by the same operator with extensive experience in optical coherence tomography (OCT) imaging (Cirrus HD-OCT; Carl Zeiss Meditec). The optic disc cube 200×200 scan protocol was used to assess RNFL thickness.

24-h IOP measurements

All of the subjects were hospitalized to perform 24-h IOP measurements. The procedure began at 0:00 a.m. on the next day after a quick adaption to the hospital environment. The IOP measurements were performed every 2 h for the next 24 h by resident ophthalmologists using an auto non-contact tonometer (NCT) (TX-F; Canon, Tokyo, Japan). The IOP measurement was taken in the sitting position and first obtained from the right eye at all time-points. Repeated measurements of IOP were performed three times and the mean values were calculated for further analysis. If one of the IOP values was 3 mmHg higher than the other two, it was discarded and repeated measurements were performed. Specifically, the IOP was measured following resting of the patients in a horizontal position during their sleeping hours. In order to obtain the routine IOP curves, the patients were encouraged to remain active within the hospital unit. In addition, their bedtime was not specified and they were permitted to have naps as desired. Systemic anti-hypertensive medications were not prohibited. Food and drink were not restricted, including alcohol and caffeine.

Statistical analysis

SPSS 20.0 (IBM Corp., Armonk, NY, USA) was used for statistical analysis. The Chi-squared test and the independent-samples t-test were used for comparisons between the two groups. The paired-samples t-test was used for comparison of basic ophthalmologic parameters and all IOP values in the two study groups. The Pearson's correlation coefficient (r) was used to evaluate the strength of association in the paired IOP data. Intra-class correlation coefficients (ICC) were calculated and Bland-Altman plots were generated to determine the agreement of IOP values between paired eyes. The interpretation of ICC values has been described as follows: A value of <0.4 represents poor agreement beyond chance, a value of 0.4-0.75 represents a moderate agreement and a value of >0.75 represents excellent agreement (15). A repeated-measures analysis of variance (ANOVA) was performed to examine the bilateral symmetry of the IOP over time. In addition, the frequency of the time difference for peak IOP time-points between the two paired eyes was analyzed using Fisher's Exact Test in the two study groups. The frequency distribution of IOP differences between bilateral eyes was calculated for all IOP values. The percentage of asymmetries of ≥2 and ≥3 mmHg was also calculated. When the minimum value was less than 5, the Yate's continuity corrected Chi-square test was used. In other circumstances, the Chi-square test was used. P<0.05 was considered to indicate a statistically significant difference for all comparisons.

Results

Patient characteristics

A total of 64 subjects comprising 32 newly diagnosed POAG patients (15 males and 17 females) and 32 age-matched normal subjects (13 males and 19 females) were enrolled in the final analysis. All of the included subjects were native Han Chinese. The average age was 47.69±15.22 (range, 26-74 years) for the glaucoma patients and 47.41±15.47 (range, 23-77 years) for the normal controls, respectively (t=0.073, P=0.942). There was also no significant intergroup difference in the gender distribution (χ2=1.890, P=0.169). In the glaucoma group, 14 right eyes and 18 left eyes had visual field defects and abnormal RNFL thickness. According to the peak IOP value throughout the 24-h period, 22 cases were hypertension glaucoma and 10 were normal tension glaucoma.

Opthalmologic data

The basic ophthalmologic data of the study groups are summarized in Table I. No inter-eye difference in CCT was present in either glaucoma subjects (P=0.472) or normal subjects (P=0.162). As expected, the affected eyes in the POAG group had worse visual field indices than the fellow eyes [P<0.001 for mean deviation (MD) and pattern standard deviation (PSD)], whereas no significant differences were observed between the paired eyes in the normal group (P=0.299 for MD, P=0.098 for PSD). Comparison of RNFL thickness in paired eyes revealed similar results in the two groups.

Table I.

Basic ophthalmologic data of the study groups.

Table I.

Basic ophthalmologic data of the study groups.

POAGNormal


VariableAffected eyeFellow eyeP-valueRight eyeLeft eyeP-value
CCT (µm)542.91±33.37541.22±34.670.472551.84±38.30549.91±35.380.162
MD (dB)−5.41±4.67−1.05±1.11<0.001−0.79±0.90−0.96±1.000.299
PSD (dB)5.95±3.931.82±0.40<0.0011.59±0.291.68±0.300.098
RNFL (µm)73.59±6.4990.81±7.36<0.00194.72±7.3593.66±7.090.059

[i] Values are expressed as the mean ± standard deviation. POAG, primary open-angle glaucoma; CCT, central cornea thickness; MD, mean deviation; PSD, pattern standard deviation; RNFL, retinal nerve fiber layer.

IOP profiles

Fig. 2 indicates the 24-h IOP rhythms in POAG patients and normal subjects. In the POAG group, the minimum IOP was at 20:00 pm, exhibited a marked increase at night and peaked at 4:00 a.m. In normal subjects, the lowest mean IOP was observed at 8:00 p.m. and the highest mean IOP at 10:00 a.m. The detailed IOP profiles of paired eyes at each time-point in each of the two study groups are listed in Tables II and III. There was no statistically significant difference between paired eyes at any of the time-points examined in the two groups (all P>0.05). The correlation coefficients for paired IOP readings indicated that the strength of association was moderate in the glaucoma group (r, 0.752-0.867) and the normal controls (r, 0.625-0.873). IOP readings at each time-point exhibited high agreements in the glaucoma group (ICC, 0.857-0.929) and the normal controls (ICC, 0.768-0.932).

Table II.

Comparison of intraocular pressure between paired eyes in glaucoma patients.

Table II.

Comparison of intraocular pressure between paired eyes in glaucoma patients.

Time-point (h)Affected eyeFellow eyeInter-eye difference (affected vs. unaffected)P-valuerICC95% CI of ICC
0:0018.34±5.5517.62±5.360.72±3.490.2520.7960.886(0.767,0.944)
2:0019.22±5.9819.83±5.82−0.62±3.040.2610.8670.929(0.854,0.965)
4:0020.19±6.9719.69±6.060.50±3.680.4480.8490.914(0.823,0.958)
6:0019.17±5.8618.83±5.470.34±3.360.5670.8270.904(0.803,0.953)
8:0018.55±6.0418.55±5.700.00±3.530.9960.8210.901(0.797,0.952)
10:0019.41±5.4619.14±4.920.27±3.330.6510.7990.886(0.766,0.944)
12:0018.34±5.4417.33±5.881.01±4.010.1630.7520.857(0.707,0.930)
14:0017.51±4.8617.68±5.06−0.17±3.050.7610.8120.896(0.787,0.949)
16:0017.77±4.9017.79±4.94−0.03±3.050.9630.8070.893(0.782,0.948)
18:0017.48±4.8717.32±5.130.17±2.780.7380.8470.916(0.829,0.959)
20:0017.30±4.8516.56±5.070.74±3.080.1840.8080.893(0.782,0.948)
22:0017.49±4.4317.06±4.450.43±2.870.4020.7910.883(0.761,0.943)

[i] Values are expressed as the mean ± standard deviation. ICC, intraclass correlation coefficient; CI, confidence interval.

Table III.

Comparison of intraocular pressure between paired eyes in normal subjects.

Table III.

Comparison of intraocular pressure between paired eyes in normal subjects.

Time-point (h)Right eyeLeft eyeInter-eye difference (right vs. left)P-valuerICC95% CI of ICC
0:0014.63±3.0214.65±3.28−0.02±2.070.9660.7860.879(0.752,0.941)
2:0015.18±3.2614.98±3.570.20±2.390.6400.7580.861(0.714,0.932)
4:0015.39±2.6815.60±3.19−0.21±2.510.6450.6480.779(0.547,0.892)
6:0015.79±2.7315.30±3.180.49±2.350.2510.6920.813(0.616,0.909)
8:0015.52±2.9516.01±2.90−0.49±1.480.0700.8730.932(0.860,0.967)
10:0015.87±2.6116.46±2.93−0.59±1.890.0870.7740.869(0.732,0.936)
12:0015.27±3.1715.33±3.21−0.07±1.970.8450.8080.894(0.783,0.948)
14:0014.74±3.0314.97±2.69−0.23±1.850.4900.7980.884(0.762,0.943)
16:0015.23±2.5315.48±2.88−0.25±1.810.4340.7840.875(0.744,0.939)
18:0015.56±2.6315.83±2.85−0.28±2.380.5180.6250.768(0.525,0.887)
20:0014.42±2.3614.70±2.63−0.28±1.840.4040.7330.843(0.678,0.923)
22:0014.90±2.7314.86±2.640.04±1.980.9080.7290.843(0.678,0.923)

[i] Values are expressed as the mean ± standard deviation. ICC, intraclass correlation coefficient; CI, confidence interval.

Differences in IOP between paired eyes

The mean IOP, peak IOP, trough IOP and IOP fluctuation were not significantly different between the paired eyes in unilateral glaucoma patients (P=0.492, P=0.338, P=0.318, P=0.883, respectively; Table IV). Furthermore, the mean IOP, peak IOP and trough IOP were in high agreement between paired eyes in glaucoma patients (ICC, 0.816-0.940). Similar results were observed in the normal controls. Figs. 3 and 4 display the Bland-Altman plots comparing the parameters of 24-h IOP profiles between the paired eyes in the POAG and normal group, respectively. In patients with unilateral glaucoma, the mean difference between paired eyes was 0.28 mmHg for the mean IOP, 0.53 mmHg for the peak IOP, 0.62 mmHg for the trough IOP and −0.09 mmHg for IOP fluctuations, while that in normal controls was −0.14 mmHg for the mean IOP, −0.50 mmHg for the peak IOP, −0.24 mmHg for the trough IOP and −0.26 mmHg for IOP fluctuations.

Table IV.

Comparison of the 24-h IOP curves between paired eyes in the study groups.

Table IV.

Comparison of the 24-h IOP curves between paired eyes in the study groups.

ParameterAffected eye or right eyeFellow eye or left eyeInter-eye differenceaP-valuerICC95% CI of ICC
Average IOP
POAG18.40±4.9118.12±4.720.28±2.300.4920.8870.940(0.877,0.971)
Normal15.21±2.2615.36±2.47−0.14±1.240.5180.8650.926(0.848,0.964)
Peak IOP
POAG22.92±6.4322.39±5.750.53±3.050.3380.8800.933(0.863,0.967)
Normal18.02±2.3718.52±2.45−0.50±1.580.0830.7850.880(0.753,0.941)
Trough IOP
POAG14.54±4.3213.92±4.370.62±3.430.3180.6890.816(0.622,0.910)
Normal12.35±2.2212.59±2.55−0.24±1.560.3890.7950.881(0.757,0.942)
IOP fluctuation
POAG8.38±3.198.47±3.99−0.09±3.470.8830.5530.701(0.388,0.854)
Normal5.68±1.555.93±1.57−0.26±1.860.4350.2930.454(−0.119,0.733)

a Inter-eye difference refers to affected-fellow in glaucoma subjects and right-left in normal controls. Values are expressed as the mean ± standard deviation. ICC, intraclass correlation coefficient; CI, confidence interval; IOP, intraocular pressure; POAG, primary open-angle glaucoma.

24-h IOP patterns in the two groups

To further characterize the concordance between the two paired eyes, repeated-measures ANOVA was performed. The results indicated that IOPs changed significantly over time in the two study groups (both P<0.001), and there was no significant eye-time interaction in either POAG patients (P=0.837) or normal subjects (P=0.897). This suggested that the 24-h IOP pattern of the paired eyes had parallel profiles in the two study groups.

IOP peak-interval timing and distribution of differences between pairs of eyes

Fig. 5 presents the distribution of eyes at different time intervals for peak IOP time-points between the paired eyes in the two groups. There was no significant difference in peak-interval timing between the two groups (Fisher's exact test, P=0.434), indicating that the intervals of peak IOP time-points were similar. Fig. 6 illustrates the frequency distributions of IOP differences for all IOPs in patients with unilateral POAG and normal subjects. The distribution in the unilateral POAG group was wider than that in the normal controls, suggesting greater asymmetry of a single pair of IOP measurements in unilateral glaucoma patients.

POAG patients have an increased frequency of absolute IOP differences of ≥2 and ≥3 mmHg between paired eyes

The proportions of cases with absolute differences of ≥2 and ≥3 mmHg between paired eyes in the different study groups are presented in Table V. It should be noted that the proportion of mean IOPs with absolute differences of ≥2 mmHg between paired eyes in the unilateral POAG group was significantly higher than that in the healthy individuals (χ2=4.480, P=0.034). In addition, there were significantly higher proportions of all IOPs with absolute differences of ≥2 and ≥3 mmHg in the unilateral POAG group compared with those in the normal control group (χ2=21.960, P<0.001; χ2=56.403, P<0.001, respectively). With regard to peak IOPs, trough IOPs and IOP fluctuations, the POAG group had higher proportions of cases with absolute IOP differences of ≥2 and ≥3 mmHg, but the differences were not statistically significant (all P>0.05).

Table V.

Proportions of subjects with absolute IOP differences of ≥2 and ≥3 mmHg between paired eyes in the POAG and normal groups (%).

Table V.

Proportions of subjects with absolute IOP differences of ≥2 and ≥3 mmHg between paired eyes in the POAG and normal groups (%).

Unilateral POAGNormal subjects


Parameter≥2 mmHg≥3 mmHg≥2 mmHg≥3 mmHg
All IOPs46.09a29.69a35.6812.50
Mean IOP34.38b15.63   9.38   0.00
Peak IOP37.5018.7534.38   0.03
Trough IOP31.2521.8828.13   0.03
IOP fluctuation46.8825.0028.13   0.09

a Significant difference from the normal control group according to the Chi-squared test.

b Significant difference from the normal control group according to Yate's continuity-corrected Chi-squared test. POAG, primary open-angle glaucoma; IOP, intraocular pressure.

Discussion

It is generally thought that IOPs between right and left eyes in healthy individuals are symmetric, and this hypothesis is commonly based on clinical experience and research studies. Asymmetric IOP results between the paired eyes have been considered as a hallmark of glaucoma (16). However, most of the early studies that analyzed the symmetry of the IOP focused on diurnal IOP curves of bilateral glaucoma patients. The correlation between asymmetric IOP and asymmetric visual field defects remains to be elucidated. To further characterize the symmetry and concordance of IOP variations between paired eyes in glaucoma, the 24-h IOP curves of untreated unilateral glaucoma patients were recorded in the present study.

The present results indicated no statistically significant differences between all IOPs, as well as the mean, peak, trough IOPs or IOP fluctuations of the paired eyes within a 24-h period in the two groups. The strength of association of all IOPs was moderate and IOP readings at each time-point were in high agreement in each study group. The repeated-measures ANOVA indicated that the 24-h IOP curves of the paired eyes had parallel profiles in the two groups. Based on the above results, a preliminary conclusion may be drawn that the 24-h IOP curves were similar and concordant between paired eyes in unilateral open-angle glaucoma. However, certain subtle differences between the 24-h IOP curves of glaucoma patients and normal subjects were noted. The frequency distribution of differences in all IOPs in unilateral POAG patients was wider than that in normal subjects, and unilateral glaucoma patients had a significantly higher proportion of all IOPs with absolute differences of ≥2 and ≥3 mmHg.

Previous studies have also examined the concordance of 24-h IOP curves between paired eyes of glaucoma patients. Chiseliţă et al (17) reported that the nictemeral variation of IOP between paired eyes in glaucoma patients were largely concordant and the 24-h IOP curves of bilateral eyes exhibited parallel changes. The study also concluded that IOP differences of ≥3 mmHg were present in 20.53% glaucoma patients with therapeutically uncontrolled IOP, which was in accordance with the present results. Dinn et al (8) reported that the diurnal IOP variations were largely concordant in untreated POAG patients as well as in POAG patients treated with the same IOP-lowering medications on each of their eyes, which was compatible with the present results. Sit et al (9) also indicated that the strength of association between right and left IOPs for untreated glaucoma patients was moderate. However, Liu and Weinreb (10) indicated that the strength of association in untreated POAG patients was significantly weaker than that in healthy individuals. One possible reason for this inconsistent result may be that the glaucoma patients in their study were part of an older population.

The results of the present study supported a presumed symmetry in the 24-h IOP curves between the paired eyes in newly diagnosed untreated POAG patients with monocular visual field defects, suggesting that an asymmetric IOP curve may not be a prerequisite for asymmetric visual field loss in the development of the disease. However, throughout the entire 24 h, the IOP in general was slightly higher in the affected eyes than in the fellow eyes, which means that an increased IOP may be a major risk factor in the development and progression of POAG. However, there is no means of determining the IOPs at the time-point at which the damage occurred. Furthermore, other factors may contribute to the asymmetric visual field loss, including vascular disorders. For instance, Plange et al (18) reported that POAG patients with asymmetric glaucomatous visual field defects exhibited asymmetric flow velocities of the central retinal artery and the ophthalmic artery.

In the present study, patients with unilateral glaucoma exhibited a wide variation in the frequency distribution of IOP differences and had significantly higher proportions of all IOPs with absolute differences of ≥2 and ≥3 mmHg, suggesting that the prevalence of IOP asymmetry in a single pair of right and left IOP measurements was increased in patients with unilateral glaucoma compared with that in normal control subjects. The increase is most probably a result of the impairment of the aqueous outflow facility in glaucoma patients (19,20). This also emphasizes the viewpoint that IOP asymmetry is more damaging than an equal increase in IOP in both eyes. Variations in IOP occur continuously and the IOPs of bilateral eyes may exhibit differential fluctuations. Therefore, caution is required when interpreting this limitation of the 24-h IOP concordance of fellow eyes in clinical practice. Further study may identify whether variations in IOP symmetry between each eye correlate with the prevalence of glaucoma.

Of note, the present study had several limitations. First, all IOP measurements were obtained using an auto non-contact tonometer. However, recent studies reported that IOPs measured by NCT were not significantly different from those measured by Goldmann applanation tonometry (21,22). Furthermore, it is well-known that IOP interpretation is affected by the CCT. However, IOP fluctuation within a 24-h cycle was assumed to be independent from CCT values in POAG patients (23). In addition, evidence indicated that the CCT changed slightly over the day and a close symmetry between the fellow eyes was observed (24,25). Second, one important variable that may affect the 24-h IOP curves is the body position. Recent studies indicated that the eye on the lower side in the lateral decubitus position had a higher IOP in glaucoma patients and healthy individuals (2629), which may be attributed to the IOP difference during the nocturnal period. Since all participants were hospitalized instead of being monitored in the sleep laboratory, the sleeping posture was not controlled. Third, the IOP values were measured every 2 h over a 24-h period rather than continuous 24-h IOP monitoring, which may have missed certain maximal and minimal IOP values. The newly developed contact lens sensor (CLS), recording the data every 5 min, may provide more detailed information (30). Previous studies have demonstrated good tolerability and high reproducibility for 24-h recording with the CLS (31,32), but the clinical applications of the CLS require to be further investigated.

The 24-h IOP curves of the paired eyes had parallel profiles in unilateral glaucoma patients and normal subjects. However, the group of unilateral glaucoma patients had a significantly larger proportion of IOP differences of ≥2 and ≥3 mmHg.

Acknowledgements

None.

Funding

No funding received.

Availability of data and materials

The data sets analysed or generated during the study are available from the corresponding author on reasonable request.

Authors' contributions

ZL, ZC and YZ were involved in the study design. ZL and SH performed ophthalmologic examinations. PH, SH and CL performed measurement and data analysis. ZL drafted the manuscript. ZC and YZ reviewed the manuscript.

Ethical approval and consent to participate

The design of the study was in compliance with the principles of the Declaration of Helsinki and the study was approved by the Ethics Committee of Ruijin Hospital, affiliated to Shanghai Jiao Tong University School of Medicine (Shanghai, China). Consent forms were signed by all of the participants prior to the examination.

Patient consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

References

1 

Tham YC, Li X, Wong TY, Quigley HA, Aung T and Cheng CY: Global prevalence of glaucoma and projections of glaucoma burden through 2040: A systematic review and meta-analysis. Ophthalmology. 121:2081–2090. 2014. View Article : Google Scholar : PubMed/NCBI

2 

Weinreb RN and Khaw PT: Primary open-angle glaucoma. Lancet. 363:1711–1720. 2004. View Article : Google Scholar : PubMed/NCBI

3 

Heijl A, Leske MC, Bengtsson B, Hyman L, Bengtsson B and Hussein M: Early Manifest Glaucoma Trial Group, Reduction of intraocular pressure and glaucoma progression: Results from the early manifest glaucoma trial. Arch Ophthalmol. 120:1268–1279. 2002. View Article : Google Scholar : PubMed/NCBI

4 

Liu JH, Sit AJ and Weinreb RN: Variation of 24-h intraocular pressure in healthy individuals: Right eye versus left eye. Ophthalmology. 112:1670–1675. 2005. View Article : Google Scholar : PubMed/NCBI

5 

Lee AJ, Rochtchina E and Mitchell P: Intraocular pressure asymmetry and undiagnosed open-angle glaucoma in an older population. Am J Ophthalmol. 137:380–382. 2004. View Article : Google Scholar : PubMed/NCBI

6 

Realini T, Barber L and Burton D: Frequency of asymmetric intraocular pressure fluctuations among patients with and without glaucoma. Ophthalmology. 109:1367–1371. 2002. View Article : Google Scholar : PubMed/NCBI

7 

Levine RA, Demirel S, Fan J, Keltner JL, Johnson CA and Kass MA: Ocular Hypertension Treatment Study Group, Asymmetries and visual field summaries as predictors of glaucoma in the ocular hypertension treatment study. Invest Ophthalmol Vis Sci. 47:3896–3903. 2006. View Article : Google Scholar : PubMed/NCBI

8 

Dinn RB, Zimmerman MB, Shuba LM, Doan AP, Maley MK, Greenlee EC, Alward WL and Kwon YH: Concordance of diurnal intraocular pressure between fellow eyes in primary open-angle glaucoma. Ophthalmology. 114:915–920. 2007. View Article : Google Scholar : PubMed/NCBI

9 

Sit AJ, Liu JH and Weinreb RN: Asymmetry of right versus left intraocular pressures over 24 hs in glaucoma patients. Ophthalmology. 113:425–430. 2006. View Article : Google Scholar : PubMed/NCBI

10 

Liu JH and Weinreb RN: Asymmetry of habitual 24-h intraocular pressure rhythm in glaucoma patients. Invest Ophthalmol Vis Sci. 55:7398–7402. 2014. View Article : Google Scholar : PubMed/NCBI

11 

Realini T, Weinreb RN and Wisniewski S: Short-term repeatability of diurnal intraocular pressure patterns in glaucomatous individuals. Ophthalmology. 118:47–51. 2011. View Article : Google Scholar : PubMed/NCBI

12 

Aptel F, Lesoin A, Chiquet C, Aryal-Charles N, Noel C and Romanet JP: Long-term reproducibility of diurnal intraocular pressure patterns in patients with glaucoma. Ophthalmology. 121:1998–2003. 2014. View Article : Google Scholar : PubMed/NCBI

13 

Prum BE Jr, Rosenberg LF, Gedde SJ, Mansberger SL, Stein JD, Moroi SE, Herndon LW Jr, Lim MC and Williams RD: Primary open-angle glaucoma preferred practice pattern(®) guidelines. Ophthalmology. 123:P112–P151. 2016. View Article : Google Scholar : PubMed/NCBI

14 

Bamdad S, Beigi V and Sedaghat MR: Sensitivity and specificity of Swedish interactive threshold algorithm and standard full threshold perimetry in primary open-angle glaucoma. Med Hypothesis Discov Innov Ophthalmol. 6:125–129. 2017.PubMed/NCBI

15 

Landis JR and Koch GG: The measurement of observer agreement for categorical data. Biometrics. 33:159–174. 1977. View Article : Google Scholar : PubMed/NCBI

16 

Williams AL, Gatla S, Leiby BE, Fahmy I, Biswas A, de Barros DM, Ramakrishnan R, Bhardwaj S, Wright C, Dubey S, et al: The value of intraocular pressure asymmetry in diagnosing glaucoma. J Glaucoma. 22:215–218. 2013. View Article : Google Scholar : PubMed/NCBI

17 

Chiseliţă D, Moţoc I and Danielescu C: Concordance of nictemeral IOP variations between fellow eyes in glaucoma and non glaucoma patients. Oftalmologia. 52:102–109. 2008.PubMed/NCBI

18 

Plange N, Kaup M, Arend O and Remky A: Asymmetric visual field loss and retrobulbar haemodynamics in primary open-angle glaucoma. Graefes Arch Clin Exp Ophthalmol. 244:978–983. 2006. View Article : Google Scholar : PubMed/NCBI

19 

Brubaker RF: Targeting outflow facility in glaucoma management. Surv Ophthalmol. 48 Suppl 1:S17–S20. 2003. View Article : Google Scholar : PubMed/NCBI

20 

Stamer WD and Acott TS: Current understanding of conventional outflow dysfunction in glaucoma. Curr Opin Ophthalmol. 23:135–143. 2012. View Article : Google Scholar : PubMed/NCBI

21 

Cook JA, Botello AP, Elders A, Fathi Ali A, Azuara-Blanco A, Fraser C, McCormack K and Margaret Burr J: Surveillance of Ocular Hypertension Study Group, Systematic review of the agreement of tonometers with Goldmann applanation tonometry. Ophthalmology. 119:1552–1557. 2012. View Article : Google Scholar : PubMed/NCBI

22 

Yilmaz I, Altan C, Aygit ED, Alagoz C, Baz O, Ahmet S, Urvasizoglu S, Yasa D and Demirok A: Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer and Tono-Pen XL. Clin Ophthalmol. 8:1069–1074. 2014. View Article : Google Scholar : PubMed/NCBI

23 

Fogagnolo P, Capizzi F, Orzalesi N, Figus M, Ferreras A and Rossetti L: Can mean central corneal thickness and its 24-h fluctuation influence fluctuation of intraocular pressure? J Glaucoma. 19:418–423. 2009. View Article : Google Scholar

24 

Myrowitz EH, Kouzis AC and O'Brien TP: High interocular corneal symmetry in average simulated keratometry, central corneal thickness and posterior elevation. Optom Vis Sci. 82:428–431. 2005. View Article : Google Scholar : PubMed/NCBI

25 

Bagga H, Liu JH and Weinreb RN: Intraocular pressure measurements throughout the 24 h. Curr Opin Ophthalmol. 20:79–83. 2009. View Article : Google Scholar : PubMed/NCBI

26 

Lee JY, Yoo C, Jung JH, Hwang YH and Kim YY: The effect of lateral decubitus position on intraocular pressure in healthy young subjects. Acta Ophthalmol. 90:e68–e72. 2012. View Article : Google Scholar : PubMed/NCBI

27 

Lee JY, Yoo C and Kim YY: The effect of lateral decubitus position on intraocular pressure in patients with untreated open-angle glaucoma. Am J Ophthalmol. 155:329–335.e2. 2013. View Article : Google Scholar : PubMed/NCBI

28 

Lee TE, Yoo C and Kim YY: Effects of different sleeping postures on intraocular pressure and ocular perfusion pressure in healthy young subjects. Ophthalmology. 120:1565–1570. 2013. View Article : Google Scholar : PubMed/NCBI

29 

Malihi M and Sit AJ: Effect of head and body position on intraocular pressure. Ophthalmology. 119:987–991. 2012. View Article : Google Scholar : PubMed/NCBI

30 

Mansouri K: The road ahead to continuous 24-h intraocular pressure monitoring in glaucoma. J Ophthalmic Vis Res. 9:260–268. 2014.PubMed/NCBI

31 

Mansouri K, Medeiros FA, Tafreshi A and Weinreb RN: Continuous 24-h monitoring of intraocular pressure patterns with a contact lens sensor: Safety, tolerability and reproducibility in patients with glaucoma. Arch Ophthalmol. 130:1534–1539. 2012. View Article : Google Scholar

32 

Mottet B, Aptel F, Romanet JP, Hubanova R, Pépin JL and Chiquet C: 24-h intraocular pressure rhythm in young healthy subjects evaluated with continuous monitoring using a contact lens sensor. JAMA Ophthalmol. 131:1507–1516. 2013. View Article : Google Scholar : PubMed/NCBI

Related Articles

Journal Cover

August-2018
Volume 16 Issue 2

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Lin Z, Huang S, Huang P, Li C, Chen Z and Zhong Y: Concordance of 24‑h intraocular pressure curve in patients with untreated unilateral primary open‑angle glaucoma. Exp Ther Med 16: 1461-1469, 2018.
APA
Lin, Z., Huang, S., Huang, P., Li, C., Chen, Z., & Zhong, Y. (2018). Concordance of 24‑h intraocular pressure curve in patients with untreated unilateral primary open‑angle glaucoma. Experimental and Therapeutic Medicine, 16, 1461-1469. https://doi.org/10.3892/etm.2018.6315
MLA
Lin, Z., Huang, S., Huang, P., Li, C., Chen, Z., Zhong, Y."Concordance of 24‑h intraocular pressure curve in patients with untreated unilateral primary open‑angle glaucoma". Experimental and Therapeutic Medicine 16.2 (2018): 1461-1469.
Chicago
Lin, Z., Huang, S., Huang, P., Li, C., Chen, Z., Zhong, Y."Concordance of 24‑h intraocular pressure curve in patients with untreated unilateral primary open‑angle glaucoma". Experimental and Therapeutic Medicine 16, no. 2 (2018): 1461-1469. https://doi.org/10.3892/etm.2018.6315