Open Access

Evaluation of the safety of MRI scans in patients undergoing dual-chamber pacemaker implantation

  • Authors:
    • Minchao Xiong
    • Nian Zhao
    • Yan Qin
    • Peng Min
    • Hong Peng
    • Yong Zhang
    • Bin Fan
  • View Affiliations

  • Published online on: July 2, 2018     https://doi.org/10.3892/etm.2018.6392
  • Pages: 1593-1596
  • Copyright: © Xiong et al. This is an open access article distributed under the terms of Creative Commons Attribution License.

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

The safety of magnetic resonance imaging (MRI) scans in patients undergoing dual-chamber pacemaker (Medtronic's EnRhythm MRI SureScan IPG (implantable pulse generator) and CapSureFix MRI pacing electrodes) implantation were evaluated. A total of 86 patients undergoing this pacemaker implantation who were admitted to Huanggang Hospital from June 2006 to March 2017 were continuously selected. On average 6.8±2.3 months after the implantation, the first MRI scan was conducted. The mean scan time was 2.2±0.9 and mean duration was 45.6±12.3 min; mean follow‑up visit period was 40.5±15.6 months, and after follow‑up, all the abnormal symptoms of patients and pacemaker abnormalities after scans were recorded. Causes of receiving MRI scans included neurological diseases (27%), spinal diseases (14%), cancers (26%), joint injuries (25%) and visceral systems (8%). A total of 12 cases (14.0%) showed significant discomfort symptoms, 10 cases (11.6%) showed pacemaker abnormalities, and the incidence rate was 25.6%. Multivariate logistic regression analysis showed that the basic types of cardiovascular diseases, dependence on pacemakers, duration of education, pacing threshold, impedance and MRI scan time were related to the occurrence of adverse scan results (p<0.05). In conclusion, MRI scans show that MRI-compatible dual-chamber pacemaker was relatively safe.
View Figures
View References

Related Articles

Journal Cover

September-2018
Volume 16 Issue 3

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Xiong M, Zhao N, Qin Y, Min P, Peng H, Zhang Y and Fan B: Evaluation of the safety of MRI scans in patients undergoing dual-chamber pacemaker implantation. Exp Ther Med 16: 1593-1596, 2018
APA
Xiong, M., Zhao, N., Qin, Y., Min, P., Peng, H., Zhang, Y., & Fan, B. (2018). Evaluation of the safety of MRI scans in patients undergoing dual-chamber pacemaker implantation. Experimental and Therapeutic Medicine, 16, 1593-1596. https://doi.org/10.3892/etm.2018.6392
MLA
Xiong, M., Zhao, N., Qin, Y., Min, P., Peng, H., Zhang, Y., Fan, B."Evaluation of the safety of MRI scans in patients undergoing dual-chamber pacemaker implantation". Experimental and Therapeutic Medicine 16.3 (2018): 1593-1596.
Chicago
Xiong, M., Zhao, N., Qin, Y., Min, P., Peng, H., Zhang, Y., Fan, B."Evaluation of the safety of MRI scans in patients undergoing dual-chamber pacemaker implantation". Experimental and Therapeutic Medicine 16, no. 3 (2018): 1593-1596. https://doi.org/10.3892/etm.2018.6392