Abstract

Following the exhaustion of all conventional hemodialysis access options in the upper extremities, a prosthetic arteriovenous loop was performed between the brachial artery (BA) and the external jugular vein (EJV) as a novel access option for hemodialysis in the present case report. During the procedure, a polytetrafluoroethylene graft was anastomosed to the BA and the EJV, and looped on the upper limb. The safety and reliability of BA-EJV access was evaluated by determining the complications, patency and intervention rates. The patient was then followed up for 20 months. The graft became thrombosed 20 months after the placement. There were no complications, such as infection, bleeding or aneurysmal lesions. Overall, the present study demonstrates that hemodialysis via BA-EJV access represents an unusual, yet effective and safe procedure, which may be conducted with acceptable complications and patency rates.

Introduction

End-stage renal disease (ESRD) is a global health concern (1), and hemodialysis access is of utmost importance to patients with ESRD who require renal replacement therapy. According to the Kidney Disease Outcomes Quality Initiative (2), autogenous arteriovenous (AV) fistula (AVF) is the recommended vascular access point for hemodialysis. However, for some patients with exhausted upper limb autogenous access options, neither renal transplantation nor peritoneal dialysis is a suitable option. As a result, the creation of a complex vascular access using an expanded polytetrafluoroethylene (PTFE) graft or access via the lower limbs may be required for such patients (3). Therefore, these patients often require more complex access procedures.

Several complex access procedures have been reported in patients with challenging circumstances. In 2008, Morsy et al (4) reported their experience with the utilization of axillary-axillary arteriovenous bypass grafts as a final alternative for patients who have experienced failure of autogenous access sites, and for whom peritoneal dialysis or transplantation are not feasible options. The procedure involves the creation of a necklace graft using internally reinforced prostheses, which are anastomosed end-to-side to the axillary artery and contralateral vein, and then tunneled directly through the subcutaneous space before reaching the sternum. The findings of this study demonstrate that these bypass grafts offer a viable solution for complex cases, with reasonable patency rates and minimal complications (4). Other options include internal jugular vein bypasses, axillary loops, femorofemoral AV crossover bypasses, superficial femoral vein transpositions, axillary artery to popliteal vein bypasses and femoral artery to right atrium bypasses (5,6). When an arteriovenous fistula cannot be established in the upper or lower limb, arterioarterial prosthetic loops have been utilized as an alternative for hemodialysis access in situations where no other option is feasible (7,8).

Although a number of complex access procedures have been described, the use of the external jugular vein (EJV) for outflow in patients with particularly challenging venous disease has rarely been reported. The external jugular vein was identified as a viable outflow conduit for arteriovenous fistulas of the upper extremity in cases where the axillary veins are occluded, exhibiting acceptable patency rates (9). In another study, the use of an ipsilateral internal jugular vein (IJV) as an AV outflow vein was examined in patients with subclavian or axillary vein stenosis or occlusion (10). The results indicated that a brachial-jugular AV graft may achieve satisfactory results in terms of patency and complication rate, although the primary patency rate decreases significantly over time. The use of the IJV as an outflow vein should be the last option for using a particular arm due to the risk of complications such as steal syndrome, seroma, hematoma, swollen arm, infections, pseudoaneurysm, bleeding from puncture site, stenosis and thrombosis (10). In the present case, a prosthetic AV loop between the brachial artery (BA) and the EJV was used for a patient whose vascular conditions did not allow for the creation of another type of upper limb access. The current study presents the experience of utilizing a PTFE graft loop anastomosis with the BA and EJV as an AV bypass graft for hemodialysis access.

Case report

A 70-year-old male patient had received maintenance hemodialysis for >10 years. In June 2015, the patient presented to Lishui Municipal Central Hospital (Lishui, China) with a complaint of lower extremity dialysis access thrombosis for 25 h. The medical history included diabetes mellitus, diabetic nephropathy, hypertension and peripheral vascular disease. Nine years previously, a left upper extremity arteriovenous fistula was created, but it lost functionality three years postoperatively. Six years previously, a right upper extremity arteriovenous fistula was established. Three years previously, a left lower extremity artificial vascular access was created using a bypass graft from the left femoral artery to the deep femoral artery. However, after 16 months, the artificial vascular access was removed due to bleeding. Two years previously, a lower extremity artificial vascular access was performed using the great saphenous vein.

A percutaneous mechanical thrombectomy was unsuccessful. A pre-operative assessment was initially performed, which included upper extremity and central venograms. Venograms of the upper arm and central veins had excluded central stenosis for the patient. The BAs were evaluated using color Doppler ultrasound (data not included). A temporary right femoral vein catheter was used for hemodialysis. Finally, the EJV was selected as the outflow vein, and inflow was performed from the left BA. It was decided that a BA-EJV AV bypass graft procedure would be performed as a permanent vascular access option.

The procedures were performed under general anesthesia, which was considered appropriate by the surgical team. The surgical procedures included the exposure of the BA and EJV, the subcutaneous placement of an expanded PTFE prosthesis with a 6-mm diameter as the loop, and a PTFE graft loop extending down into the mid-forearm, for which a forearm incision was required. Following the separation of the BA and EJV, a PTFE graft was positioned following the configuration of a subcutaneously tunneled loop on the upper limb. A 6-0 polypropylene suture was used in the creation of side-to-end or end-to-end anastomoses between the BA or EJV and graft. The length of the implanted graft was 60 cm. The duration of the surgery was 90 min, and the amount of blood lost was 100 ml.

Post-operative complications included temporary arm swelling for 2 weeks. Subcutaneous administration of low molecular weight heparin (4,000 units) once daily was initiated for a duration of 3 days and subsequently discontinued. Upon discharge, the patient was prescribed aspirin (100 mg/day) as an antiplatelet therapy. The patient was assessed at a 2-week post-operative follow-up by the surgeon. Subsequently, the access nurse evaluated the graft during dialysis sessions to ensure the patency. In addition, nephrology physicians advise against repeated punctures at the same site and recommend puncturing at different points with intervals of >1 week. Blood flow of the graft was excellent for hemodialysis. Post-operative computed tomography angiography of the access revealed a patent anastomosis (Fig. 1). The patency of the graft continued for 20 months. The graft became thrombosed 20 months after the placement. However, the patient refused to undergo a thrombectomy surgery. A cuffed catheter was placed in the right femoral vein for long-term hemodialysis. The patient succumbed to hypertensive intracerebral hemorrhage unrelated to hemodialysis access, 25 months post-surgery.

Discussion

Optimal vascular access for hemodialysis is characterized by a low rate of associated complications, the ability to deliver adequate flow rates and long-lasting patency. It is generally known that AVF has fewer associated complications, a longer patency, fewer interventions required and lower costs than AVGs or catheters. Therefore, AVF is the primary choice for hemodialysis access (11). However, the number of patients who have multiple AVF failures and require complex vascular access is increasing. In the case described in the present study, the patient had exhausted all other options for upper extremity access. For patients without options via the upper extremities, AV or arterial-arterial grafts on the lower extremities have been previously reported (7,8,12,13). However, a femoral vein transposition or arterioarterial prosthetic loops are associated with a high risk of ischemic complications, and are not suitable for patients with peripheral artery disease. Therefore, lower extremity vascular access should be carefully tailored to each individual patient (12).

For patients in whom upper limb access is not obtainable, thigh AV access has been reported as a viable option (14). It has been shown that prosthetic AV access in the leg is associated with a low risk of Steal syndrome, including symptoms/complaints of pain, numbness, coldness and weakness in the affected limb; however, it is accompanied by low primary and secondary patency rates, a particularly high infection rate and more frequent surgical revisions (15). Axillorenal AVG and right atrial bypass grafting have also been previously reported (16,17). However, the loop requires an anastomosis to the renal vein or to the right atrial appendage through a median sternotomy, which is considered to be a complex access configuration. In addition, chest wall or arm AVGs based on the axillary artery and ipsilateral axillary vein are well described in the absence of central vein occlusion (18-20). In the present case, AVF construction had failed and the creation of complex grafts based on the axillary vein was not feasible for the patient. Thus, a novel AVG procedure for hemodialysis based on the EJV and BA was created as the upper body access option.

In the present patient, previous upper or lower limb vascular access and central venous catheter use had failed multiple times, and the incidence of central venous stenosis was high. The presence of central venous stenosis or obstruction is a contraindication to this BA-EJV access. Thus, it is suggested that pre-operative venography is required when the clinical suspicion or history of central venous stenosis exists. If central venous stenosis is identified, percutaneous transluminal angioplasty or a stent is required. If central venous occlusion is identified, re-cannulation of the central vein is necessary. According to previous studies, lower limb access is required in patients whose occlusion cannot be treated (13,18). In the case in the present study, an increase in the risk of developing thrombosis after the BA-EJV procedure was considered; therefore, the patient was treated with a post-operative oral antithrombotic drug. However, the risk of post-operative hemorrhagic complications needs to be carefully evaluated.

In the present patient, the BA-EJV graft maintained patency for >20 months. The patient also did not experience any severe complications, such as hemorrhaging, infection and aneurysmal dilatation. These results were considered acceptable with respect to the lack of vascular access in the patient. Based on the present study, it is considered that the BA-EJV may represent a novel hemodialysis access option.

Although BA-EJV grafting is an acceptable procedure for establishing upper limb hemodialysis access, this process may be accompanied by complications that require early treatment and recognition. For example, graft infection requires the use of systemic antibiotics, or a total or subtotal graft excision (21). In addition, venous anastomotic stenosis leads to prosthetic graft thrombosis. Previous studies have demonstrated that venous anastomotic stenosis typically occurs in the first year after the procedure (22,23). Furthermore, heart failure is the most frequent cardiovascular disease associated with grafting or fistula formation, due to the marked hemodynamic changes related to the large increase in blood flow (24-26). It may be suggested that patients with heart failure classified as New York Heart Association Class IV are not suitable candidates for BA-EJV access (27). Finally, BA-EJV access may result in hematomas, arterial steal syndrome, ischemic monomelic neuropathy or the formation of an aneurysm (27). Previous studies have suggested that pseudoaneurysms occur in ~10% of PTFE grafts (23,28). The use of BA-EJV GRAFT may also lead to the development of pseudoaneurysms resulting from repeated puncture or graft material deterioration. In the present case, pseudoaneurysm formation was not observed, as a careful puncture technique was applied.

It should be noted that although acceptable results were obtained for the patient described in the present study, the lack of a control group was one limitation to the report. There were also specific neck mobility issues in the patient. Furthermore, it was noted that the graft crossed the elbow crease in two areas, which could lead to the kinking of the graft upon flexion at the elbow. The indications for BA-EJV GRAFT need to be clearly defined due to the aforementioned potential complications. AVF remains the preferred access option for hemodialysis, and BA-EJV GRAFT may be utilized as a second line procedure only for patients in whom other upper extremity possibilities for AV access creation are exhausted.

In conclusion, the present study describes the case of a patient in which the BA-EJV GRAFT was used as an alternative approach for hemodialysis access as all other conventional vascular access options had been exhausted. However, further carefully designed studies are required in the future to perform more robust comparisons of BA-EJV GRAFT with other access methods.

Acknowledgements

Not applicable.

Funding

Funding: The present study was financially supported by the Medical and Health Science Technology Plan Project from Zhejiang, China (grant no. 2020ZH082).

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Authors' contributions

WL contributed to the conception and design of the study, treated and followed up patients, and collected the data. JX advised on patient treatment and surgery. HL was responsible for obtaining medical images and analyzing patient data. WL and JX confirm the authenticity of all the raw data. All authors have read and approved the manuscript.

Ethics approval and consent to participate

Not applicable.

Patient consent for publication

Written informed consent was obtained from the patient for the publication of their data and any related images.

Competing interests

The authors declare that they have no competing interests.

References

1 

Anderson S, Halter JB, Hazzard WR, Himmelfarb J, Horne FM, Kaysen GA, JW Nayfield SG, Schmader K, Tian Y, et al: Prediction, progression, and outcomes of chronic kidney disease in older adults. J Am Soc Nephrol. 20:1199–1209. 2009.PubMed/NCBI View Article : Google Scholar

2 

Vascular Access 2006 Work Group. Clinical practice guidelines for vascular access. Am J Kidney Dis. 48 (Suppl 1):S176–S247. 2006.PubMed/NCBI View Article : Google Scholar

3 

Hedin U: Long-term results of PTFE grafts. J Vasc Access. 16 (Suppl 9):S87–S92. 2015.PubMed/NCBI View Article : Google Scholar

4 

Morsy MA, Khan A and Chemla ES: Prosthetic axillary-axillary arteriovenous straight access (necklace graft) for difficult hemodialysis patients: A prospective single-center experience. J Vasc Surg. 48:1251–1254.e1. 2008.PubMed/NCBI View Article : Google Scholar

5 

Hazinedaroğlu S, Karakayali F, Tüzüner A, Ayli D, Demirer S, Duman N and Yerdel MA: Exotic arteriovenous fistulas for hemodialysis. Transplant Proc. 36:59–64. 2004.PubMed/NCBI View Article : Google Scholar

6 

Rajan DK: New approaches to arteriovenous fistula creation. Semin Intervent Radiol. 33:6–9. 2016.PubMed/NCBI View Article : Google Scholar

7 

Lei W, Ji J, Wang J, Jin L and Zou H: Arterioarterial prosthetic loop as an alternative approach for hemodialysis access. Medicine (Baltimore). 94(e1645)2015.PubMed/NCBI View Article : Google Scholar

8 

Zanow J, Kruger U, Petzold M, Petzold K, Miller H and Scholz H: Arterioarterial prosthetic loop: A new approach for hemodialysis access. J Vasc Surg. 41:1007–1012. 2005.PubMed/NCBI View Article : Google Scholar

9 

Moini M, Rasouli MR and Cheraghi A: The external jugular vein: An alternative outflow for insertion of upper extremity arteriovenous grafts in patients with obstructed axillary vein. Ann Vasc Surg. 24(573)2010.PubMed/NCBI View Article : Google Scholar

10 

Kim MJ, Yun S, Song D, Cho SW, Goo DE, Kim YJ and Choi D: Alternative venous outflow by brachial to jugular vein vascular access for hemodialysis in the exhausted upper extremities. J Vasc Access. 16:269–274. 2015.PubMed/NCBI View Article : Google Scholar

11 

Ashby D, Borman N, Burton J, Corbett R, Davenport A, Farrington K, Flowers K, Fotheringham J, Andrea Fox RN, Franklin G, et al: Renal association clinical practice guideline on haemodialysis. BMC Nephrol. 20(379)2019.PubMed/NCBI View Article : Google Scholar

12 

Wilmink T: Lower limb access. J Vasc Access. 15 (Suppl 7):S130–S135. 2014.PubMed/NCBI View Article : Google Scholar

13 

Antoniou GA, Lazarides MK, Georgiadis GS, Sfyroeras GS, Nikolopoulos ES and Giannoukas AD: Lower-extremity arteriovenous access for haemodialysis: A systematic review. Eur J Vasc Endovasc Surg. 38:365–372. 2009.PubMed/NCBI View Article : Google Scholar

14 

Gibbons CP: Vascular access in the lower limb. Endovasc Surg. 38:373–374. 2009.PubMed/NCBI View Article : Google Scholar

15 

Oh E, Kim YJ, Goo DE, Yang S and Hong S: Percutaneous transluminal angioplasty for dysfunctional femoral hemodialysis graft. Diagn Interv Radiol. 21:154–159. 2015.PubMed/NCBI View Article : Google Scholar

16 

Karp SJ, Hawxby A and Burdick JF: Axillorenal arteriovenous graft: A new approach for dialysis access. J Vasc Surg. 40:379–380. 2004.PubMed/NCBI View Article : Google Scholar

17 

El-Sabrout RA and Duncan JM: Right atrial bypass grafting for central venous obstruction associated with dialysis access: another treatment option. J Vasc Surg. 29:472–478. 1999.PubMed/NCBI View Article : Google Scholar

18 

Liechty JM, Fisher T, Davis W, Oglesby WC, Bennett M, Grimsley B and Shutze W: Experience with chest wall arteriovenous grafts in hemodialysis patients. Ann Vasc Surg. 29:690–697. 2015.PubMed/NCBI View Article : Google Scholar

19 

Hunter JP and Nicholson ML: Midterm experience of ipsilateral axillary-axillary arteriovenous loop graft as tertiary access for haemodialysis. J Transplant. 2014(908738)2014.PubMed/NCBI View Article : Google Scholar

20 

Mohamed IH, Bagul A, Doughman T and Nicholson ML: Axillary-axillary loop graft for hemodialysis access. J Vasc Access. 12:262–263. 2011.PubMed/NCBI View Article : Google Scholar

21 

Nguyen DB, Arduino MJ and Patel PR: Hemodialysis-associated infections. Chronic Kidney Disease, Dialysis and Transplantation 389-410.e8, 2019.

22 

Martin C and III Pillai R: Dialysis access anatomy and interventions: A primer. Semin Intervent Radiol. 33:52–55. 2016.PubMed/NCBI View Article : Google Scholar

23 

Rose DA, Sonaike E and Hughes K: Hemodialysis access. Surg Clin North Am. 93:997–1012, x. 2013.PubMed/NCBI View Article : Google Scholar

24 

Roca-Tey R: Permanent arteriovenous fistula or catheter dialysis for heart failure patients. J Vasc Access. 17 (Suppl 1):S23–S29. 2016.PubMed/NCBI View Article : Google Scholar

25 

Wasse H and Singapuri MS: High-output heart failure: How to define it, when to treat it, and how to treat it. Semin Nephrol. 32:551–557. 2012.PubMed/NCBI View Article : Google Scholar

26 

Singh S, Elramah M, Allana SS, Babcock M, Keevil JG, Johnson MR, Yevzlin AS and Chan MR: A case series of real-time hemodynamic assessment of high output heart failure as a complication of arteriovenous access in dialysis patients. Semin Dial. 27:633–638. 2014.PubMed/NCBI View Article : Google Scholar

27 

Malik J, Lomonte C, Rotmans J, Chytilova E, Roca-Tey R, Kusztal M, Grus T and Gallieni M: Hemodialysis vascular access affects heart function and outcomes: Tips for choosing the right access for the individual patient. J Vasc Access. 22 (Suppl 1):32–41. 2021.PubMed/NCBI View Article : Google Scholar

28 

Kakkos SK, Topalidis D, Haddad R, Haddad GK and Shepard AD: Long-term complication and patency rates of Vectra and IMPRA Carboflo vascular access grafts with aggressive monitoring, surveillance and endovascular management. Vascular. 19:21–28. 2011.PubMed/NCBI View Article : Google Scholar

Related Articles

Journal Cover

January-2024
Volume 27 Issue 1

Print ISSN: 1792-0981
Online ISSN:1792-1015

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Lei W, Lai H and Xin J: Prosthetic brachial artery-external jugular vein arteriovenous grafts as a novel option for hemodialysis access: A case report. Exp Ther Med 27: 2, 2024
APA
Lei, W., Lai, H., & Xin, J. (2024). Prosthetic brachial artery-external jugular vein arteriovenous grafts as a novel option for hemodialysis access: A case report. Experimental and Therapeutic Medicine, 27, 2. https://doi.org/10.3892/etm.2023.12289
MLA
Lei, W., Lai, H., Xin, J."Prosthetic brachial artery-external jugular vein arteriovenous grafts as a novel option for hemodialysis access: A case report". Experimental and Therapeutic Medicine 27.1 (2024): 2.
Chicago
Lei, W., Lai, H., Xin, J."Prosthetic brachial artery-external jugular vein arteriovenous grafts as a novel option for hemodialysis access: A case report". Experimental and Therapeutic Medicine 27, no. 1 (2024): 2. https://doi.org/10.3892/etm.2023.12289