Open Access

Clinical utility of the Xpert MRSA assay for early detection of methicillin-resistant Staphylococcus aureus

  • Authors:
    • Ae-Chin Oh
    • Jin Kyung Lee
    • Ha Na Lee
    • Young Jun Hong
    • Yoon Hwan Chang
    • Seok-Il Hong
    • Dong Ho Kim
  • View Affiliations

  • Published online on: October 9, 2012     https://doi.org/10.3892/mmr.2012.1121
  • Pages: 11-15
  • Copyright: © Oh et al. This is an open access article distributed under the terms of Creative Commons Attribution License [CC BY_NC 3.0].

Metrics: Total Views: 0 (Spandidos Publications: | PMC Statistics: )
Total PDF Downloads: 0 (Spandidos Publications: | PMC Statistics: )


Abstract

Methicillin-resistant Staphylococcus aureus (MRSA) is responsible for many nosocomial and community-acquired infections, resulting in significant morbidity and mortality. A practical way to limit the spread of MRSA is early detection and proper treatment. However, screening culture for MRSA typically requires 2-3 days. The Xpert MRSA assay (Cepheid, Sunnyvale, CA, USA) is a real-time polymerase chain reaction-based assay developed for screening an MRSA-specific DNA sequence within the staphylococcal cassette chromosome in 2 h. Lower respiratory tract specimens, such as transtracheal aspirates (TTAs) and bronchoalveolar lavage fluid (BALF), are commonly obtained from intubated patients. Therefore, using the lower respiratory tract specimens with the Xpert MRSA assay may be a practical tool for patient care. We performed the Xpert MRSA assay on 108 TTA and 21 BALF specimens from 92 patients and compared the results to those obtained by culture. The two assays showed concordant results in 120 (93.0%) cases and discordant results in 9 (7.0%) cases, which were culture‑negative and Xpert MRSA-positive. Among the discordant cases, 5 patients developed culture-positive samples 2-15 days after the Xpert MRSA detected MRSA. We conclude that the Xpert MRSA assay is a rapid, sensitive and clinically useful test, particularly for the early detection of MRSA.

Introduction

Staphylococcus aureus is a well-documented opportunistic human pathogen and a major nosocomial pathogen that causes a range of diseases. Infections caused by S. aureus range from skin and soft-tissue infections, to pneumonia and bacteremia. Methicillin was introduced as an agent to treat staphylococcal infections in 1959 (1). However, methicillin-resistant Staphylococcus aureus (MRSA) strains were identified by 1960. MRSA is responsible for many nosocomial and community-acquired infections and results in significant morbidity and mortality (1,2). It is critical to limit the spread of MRSA in health care settings. A practical way to limit the spread of MRSA is early detection and appropriate treatment of the infection (3). The standard methods used for MRSA detection include the use of oxacillin-salt agar plates, disk-diffusion susceptibility testing and an automated MRSA identification system (i.e., Microscan® and Vitek®) (4). However, screening samples for MRSA typically requires 2–3 days (4), and such a delay in diagnosis allows MRSA to spread. Advances in molecular diagnostics have enabled the use of real-time polymerase chain reaction (PCR) for detecting and monitoring organisms in clinical specimens (6). The majority of the molecular tests for MRSA detect the presence of the mecA gene, and this gene is also carried by certain methicillin-susceptible Staphylococcus aureus (MSSA) and methicillin-resistant coagulase-negative staphylococci (MRCNSs) (7). To avoid a false-positive result, it is necessary to target a gene specific to methicillin-resistant S. aureus(7,8). The Xpert MRSA assay (Cepheid) has been developed for screening an MRSA-specific DNA sequence within the staphylococcal cassette chromosome mec (SCCmec), found only in S. aureus and not in other staphylococci (9). This is a real-time PCR-based assay that automates and integrates all the steps of SCCmec detection from DNA extraction to detection of the target organism within 2 h. The Xpert MRSA kit has been approved for the screening of MRSA in nasal swab specimens (10). However, there are questions as to whether body sites other than the nose should be sampled for MRSA surveillance (11). Lower-respiratory-tract specimens such as transtracheal aspirates (TTAs) and bronchoalveolar lavage fluid (BALF) are often required in intubated patients and patients from whom suitable respiratory secretions cannot be obtained (12). The Xpert MRSA assay using lower-respiratory tract specimens may be useful for diagnosing respiratory infection by MRSA. The aim of this study was to evaluate and compare the clinical usefulness of the Xpert MRSA assay with culture methods for the early detection of lower respiratory infection by MRSA. We evaluated the speed, reliability and clinical usefulness of the Xpert MRSA assay and analyzed the applicability of this rapid assay in clinical microbiological laboratories.

Materials and methods

Specimen selection

Lower-respiratory-tract specimens such as TTA and BALF were obtained from 92 patients who were hospitalized in the Intensive Care Unit of Korea Cancer Center Hospital and sent to our clinical microbiology laboratory for routine culture to diagnose respiratory infection. After the culture was completed, the left-over specimens were anonymized and submitted to the biorepository in our institute (KIRAMS Radiation Biorepository, KRB), with the informed consent of the patients or guardians. For the Xpert MRSA assay, the specimens were distributed from the KRB. This protocol was approved by the institutional review board of the Korea Institute of Radiological and Medical Sciences (K-1111-002-017).

Culture and identification of MRSA

One swab was obtained from each specimen and streaked onto a blood agar plate and incubated in 5% CO2 at 36°C for 24 h. When the colonies were suspected to be those of S. aureus on the basis of their morphology, they were tested with a Vitek 2 gram-positive identification card (bioMerieux, Marcy l’Étoile, France) for identification. Methicillin resistance was then determined by measuring the minimum concentration of oxacillin required to inhibit the bacteria using the Vitek broth culture system (bioMerieux).

Xpert MRSA assay

The Xpert MRSA assay was performed using a GeneXpert® Dx system that carries out the PCR process using an Xpert MRSA cartridge containing PCR reagents to detect SCCmec. Specimens for the Xpert MRSA assay were disseminated from the KIRAMS Radiation Biorepository. One swab from each archived specimen was suspended into a tube containing elusion reagents. The elusion tubes, containing guanidinium thiocyanate and surfactants, were vortexed at a high speed for 10 sec. The mixture was added to the ‘S’ chamber of the Xpert MRSA cartridge. A solution of sodium hydroxide (reagent 1) was pipetted into chamber 1, while a second reagent (Tris-buffer, EDTA and surfactants) was pipetted into chamber 2 of the cartridge. The prepared cartridge was inserted into the GeneXpert Dx instrument within 15 min of adding the reagents to the cartridge. The analysis was performed as per the manufacturer’s amplification protocol. PCR reactions are considered invalid when the specimens do not meet the acceptance criteria for sample-processing control (SPC). On the basis of the cut-off value of 30 for the threshold cycle (Ct), the PCR results were interpreted to be positive or negative.

Comparison of the culture method and the Xpert MRSA assay

We categorized the initial culture results as positive or negative for MRSA. The Xpert MRSA assay results were also categorized as positive and negative. The results of the two assays were compared, and each case was classified as concordant or discordant, according to the agreement between the two results. Medical records were reviewed for the discordant group to evaluate the infection history prior to and following the culture test. The concordant MRSA-infected group and discordant early-detected MRSA group were considered as true positives for MRSA infection. We evaluated the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and false-positive rate of the Xpert MRSA assay.

Results

Comparison of the results of culture and Xpert MRSA assay

Out of 129 specimens (108 TTA and 21 BALF) from 92 patients, the Xpert MRSA assay and culture identified 42 (32.6%) and 32 (24.8%) positive specimens, respectively. The patients (65 males and 27 females, median age of 71 years) had various types of cancer. None of the tested specimens were excluded as they all showed valid PCR reactions. Concordant results between the two assays were observed in 120 (93.0%) specimens and discordant results were observed in 9 (7.0%) specimens. All the culture-positive specimens were also tested positive by the Xpert MRSA assay.

Clinical characteristics of the concordant and discordant cases

Out of the 120 concordant cases, 33 were positive according to Xpert MRSA and culture, which were categorized as MRSA infected, and 87 were negative according to Xpert MRSA and culture, which were categorized as non-infected. All 9 (7.0%) discordant cases showed negative culture and positive Xpert MRSA results (Table I). We reviewed the medical records of the discordant cases. Five (3.9%) out of the 9 cases showed positive results in the next culture test (categorized as ‘early detection’), and the time interval between the positive Xpert MRSA and the positive culture ranged from 2 to 15 days (mean, 8 days). For the 4 (3.1%) remaining cases, the patients had been infected with MRSA in the previous week (categorized as ‘previous infection’), and the time intervals ranged from 1 to 7 days (mean, 4.5 days) (Table II). As we regarded the concordant MRSA-infected group and the early-detected MRSA group as true-positives, the 4 (3.1%) cases of previous infection were concluded to be false-positive. The sensitivity, specificity, PPV and NPV of the Xpert MRSA assay were 100, 90.7, 78.0 and 100%, respectively.

Table I

Comparison of the results of culture and Xpert MRSA assay.

Table I

Comparison of the results of culture and Xpert MRSA assay.

Xpert

+Total
Culture
 +33033
 −98796
Total4287129

[i] Xpert, Xpert MRSA assay; +, positive; −, negative; MRSA, methicillin- resistant Staphylococcus aureus.

Table II

Clinical specifications of the 9 discordant cases which showed positive Xpert MRSA and negative culture.

Table II

Clinical specifications of the 9 discordant cases which showed positive Xpert MRSA and negative culture.

Assay results

CaseGender/age1st2nd3rdInterval between Xpert(+)and culture(+)aStatebMRSA decisionc
1M/67Xpert++ND+2 daysEarly detectionTP
Culture+ND
2M/80Xpert++ND+3 daysEarly detectionTP
Culture+ND
3M/71Xpert+++5 daysEarly detectionTP
Culture+
4F/75Xpert++ND+15 daysEarly detectionTP
Culture+
5M/90Xpert+NDND+15 daysEarly detectionTP
Culture+ND
6F/93Xpert++ND−1 dayPrevious infectionFP
Culture+ND
7M/74Xpert+++−4 daysPrevious infectionFP
Culture++
8M/83XpertNT+ND−6 daysPrevious infectionFP
Culture+ND
9M/80Xpert+++−7 daysPrevious infectionFP
Culture++

a Subtraction of culture-positive day from Xpert-positive day. Positive and negative values represent early detection and previous infection, respectively. Calculation for early detected cases used the date of the first positive result, and previously infected cases used the date of the last positive result.

b Meaning of the discordant Xpert assay result based on interval between 2 assays for positive results.

c Our interpretation of the Xpert result.

{ label (or @symbol) needed for fn[@id='tfn5-mmr-07-01-0011'] } Early detections were considered as TP according to our design. Xpert, Xpert MRSA assay; NSCLC, non-small cell lung cancer; ND, not done; TP, true-positive; FP, false-positive; M, male; F, female.

Discussion

Since delayed detection of MRSA increases the transmission of MRSA among hospitalized patients, rapid and accurate detection is extremely valuable for infection control in clinical settings (20). Although culture-based methods have been the standard methods used to detect MRSA, 2–3 days are required to obtain results by these methods (5). Real-time PCR-based tests, including the Xpert MRSA assay, have been developed and widely used as the technique is simple, sensitive and takes less than 2 h (13). Since the Xpert MRSA assay has been approved for screening MRSA in nasal swab specimens, we aimed to assess the feasibility of lower-respiratory tract specimens such as TTA and BALF. In this study, all the specimens met the acceptance criteria, which verify adequacy of specimen processing and absence of inhibitors of the PCR reaction. TTA and BALF for routine culture were also optimal for the Xpert MRSA assay, and the rapidity of the technique makes this assay more useful for patient care and infection control, with the potential for a reduction in health care costs (4,21).

The majority of the MRSA screening methods focus on detecting the mecA gene. This structural gene is responsible for methicillin resistance via the production of an altered penicillin-binding protein, which maintains staphylococcal cell-wall integrity due to its low affinity to β-lactam antibiotics. The mecA gene is present within a transposon-encoded genetic region known as the SCCmec(14). If a molecular assay targets only for the mecA gene, MSSAs and MRCNSs carrying the mecA gene may provide false-positive results (8). False-positive results may be explained by the presence of amplifiable DNA originating from non-viable strains in treated patients, genetic excision within the SCCmec region, low sensitivity of the culture, or mixed-culture cocktails of MSSA in the absence of MRSA (10,1517). Presence of dead MRSA cells yields positive results and accounts for the majority of the false-positive results. The duration for which dead MRSA cells can be detected by PCR will be a notable subject for future studies. Genetic excisions within the SCCmec region of the MRSA strains in the absence of a functional mecA gene may also yield positive PCR results. Thus, these ‘empty cassette variants’ lead to PCR-positive and culture-negative results. These MSSAs are misidentified as MRSA and in fact lead to false-positive PCR results (11,14,15). However, this error does not occur in the case of the Xpert MRSA assay, as it screens for an MRSA-specific DNA sequence within the SCCmec. Discrepant results may be due to the differences in the lower limits of detection of the PCR assay. Rossney et al have previously reported that the detection limit of agar cultures is 171 CFU/swab, whereas those for broth cultures and the Xpert MRSA assay are 9 CFU/swab and 58 CFU/swab, respectively (16). Positive results in the case of the non-MRSA infected group were due to the presence of other organisms misidentified as MRSA. Cross-reactions may occur when non-MRSA strains are infected together with MRSA. Another study pointed out that the sensitivity for MRSA strains in mixtures spiked with non-MRSA strains is higher than that for pure MRSA strains (9).

Sputum specimens are often collected from intubated patients, wherein complete elimination of contamination by resident oral bacteria is impossible (12). Specimens obtained from the lower respiratory tract are tested in order to detect the pathogen causing hospital-acquired pneumonia (12). Invasive methods for collecting specimens such as TTA or BALF are indicated when appropriate respiratory secretions cannot be obtained (12).

Our study has a few limitations. Firstly, the culture result was not confirmed for the presence of MRSA by more sensitive techniques. For bacterial culture, we do not use broth enrichment media or selective agar as a routine procedure. Therefore, we implemented the same procedure as our routine culture and compared it with the Xpert MRSA assay. The isolation rate of MRSA with broth enrichment or selective agar is higher than that with agar culture alone, but the technique is not always beneficial to every clinical laboratory due to workload and turnaround time (18). Secondly, the specimens we used have not been clinically approved to date. However, a nasal swab, which is the only approved specimen for MRSA screening using the Xpert MRSA assay, is not always the best specimen. A previous study showed that MRSA nasal colonization was a poor predictor of subsequent MRSA infection. They pointed out that 72.5% of the patients with lower respiratory infection with MRSA and 73.1% of the patients with blood stream infection with MRSA showed negative results for nasal colonization (19). Therefore, an effort to gather appropriate specimens should be made.

In conclusion, the Xpert MRSA assay is a simple, rapid and sensitive technique to detect MRSA and may be beneficial for early detection in a clinical laboratory.

Acknowledgements

The specimens used for the Xpert MRSA assay were distributed by the KIRAMS Radiation Biorepository (KRB) according to the recommended procedure. This study was supported by a grant from the Radiation Bio-Resource Research Program of the Korea Institute of Radiological and Medical Sciences (No. 740802).

References

1 

Kim TS, Yi JY, Hong KH, Park JS and Kim EC: Distribution of virulence genes in spa types of methicillin-resistant Staphylococcus aureus isolated from patients in intensive care units. Korean J Lab Med. 31:30–36. 2011. View Article : Google Scholar : PubMed/NCBI

2 

Van Hal SJ, Stark D, Lockwood B, Marriott D and Harkness J: Methicillin-resistant Staphylococcus aureus (MRSA) detection: comparison of 2 molecular methods (IDI-MRSA PCR assay and GenoType MRSA direct PCR assay) with 3 selective MRSA agars (MRSA ID, MRSASelect, and CHROMagar MRSA) for use with infection-control swabs. J Clin Microbiol. 45:2486–2490. 2007.

3 

Hope WW, Morton AP, Looke DF, Schooneveldt JM and Nimmo GR: A PCR method for the identification of Staphylococcus aureus (MRSA) from screening swabs. Pathology. 36:265–268. 2004.PubMed/NCBI

4 

Stratidis J, Bia FJ and Edberg SC: Use of real-time polymerase chain reaction for identification of methicillin-resistant Staphylococcus aureus directly from positive blood culture bottles. Diagn Microbiol Infect Dis. 58:199–202. 2007. View Article : Google Scholar : PubMed/NCBI

5 

Thomas LC, Gidding HF, Ginn AN, Olma T and Iredell J: Development of a real-time Staphylococcus aureus and MRSA (SAM) PCR for routine blood culture. J Microbiol Methods. 68:296–302. 2007.

6 

Ulrich MP, Christensen DR, Coyne SR, et al: Evaluation of the Cepheid GeneXpert system for detecting Bacillus anthracis. J Appl Microbiol. 100:1011–1016. 2006. View Article : Google Scholar : PubMed/NCBI

7 

Park SH, Jang YH, Sung HS, Kim MN, Kim JS and Park YJ: Performance evaluation of BD GeneOhm MRSA PCR assay for detection of nasal colonization of methicillin-resistant Staphylococcus aureus at endemic intensive care unit. Korean J Lab Med. 29:439–447. 2009.(In Korean).

8 

Oberdorfer K, Pohl S, Frey M, Heeg K and Wendt C: Evaluation of a single-locus real-time polymerase chain reaction as a screening test for specific detection of Staphylococcus aureus in ICU patients. Eur J Clin Microbiol Infect Dis. 25:657–663. 2006. View Article : Google Scholar : PubMed/NCBI

9 

Malhotra-Kumar S, Van Heirstraeten L, Lee A, et al: Evaluation of molecular assays for rapid detection of methicillin-resistant Staphylococcus aureus. J Clin Microbiol. 48:4598–4601. 2010. View Article : Google Scholar : PubMed/NCBI

10 

Laurent C, Bogaerts P, Scoevaerdts D, et al: Evaluation of the Xpert MRSA assay for rapid detection of methicillin-resistant Staphylococcus aureus from nares swabs of geriatric hospitalized patients and failure to detect a specific SCCmec type IV variants. Eur J Clin Microbiol Infect Dis. 29:995–1002. 2010.PubMed/NCBI

11 

Paule SM, Hacek DM, Kufner B, et al: Performance of the BN GeneOhm methicillin-resistant Staphylococcus aureus test before and during high-volume clinical use. J Clin Microbiol. 45:2993–2998. 2007.

12 

Japanese Respiratory Society. Diagnosis of hospital-acquired pneumonia and methods of testing for pathogen. Respirology. 14:S10–S22. 2009. View Article : Google Scholar : PubMed/NCBI

13 

Kluytmans J: Control of Staphylococcus aureus (MRSA) and the value of rapid tests. J Hosp Infect. 65:100–104. 2007.

14 

Wolk DM, Picton E, Johnson D, et al: Multicenter evaluation of the Cepheid Xpert methicillin-resistant Staphylococcus aureus (MRSA) test as a rapid screening method for detection of MRSA in Nares. J Clin Microbiol. 47:758–764. 2009. View Article : Google Scholar : PubMed/NCBI

15 

Roisin S, Laurent C, Nonhoff C, et al: Positive predictive value of the Xpert MRSA assay diagnostic for universal patient screening at hospital admission: influence of the local ecology. Eur J Clin Microbiol Infect Dis. 31:873–880. 2011. View Article : Google Scholar

16 

Rossney AS, Herra CM, Brennan GI, Morgan PM and O’Connell BO: Evaluation of the Xpert methicillin-resistant Staphylococcus aureus (MRSA) assay using the GeneXpert real-time PCR platform for rapid detection of MRSA from screening specimens. J Clin Microbiol. 46:3285–3290. 2008.PubMed/NCBI

17 

San ND, Denis O, Gasasira MF, De Mendona, Nonhoff C and Struelens MJ: Controlled evaluation of the IDI-MRSA assay for detection of colonization by methicillin-resistant Staphylococcus aureus in diverse mucocutaneous specimens. J Clin Microbiol. 45:1098–1101. 2007. View Article : Google Scholar : PubMed/NCBI

18 

Kelly PG, Grabsch EA, Howden BP, Gao W and Grayson ML: Comparison of the Xpert methicillin-resistant Staphylococcus aureus (MRSA) PCR assay, BD GeneOhm MRSA assay, and culture for detection of nasal and cutaneous groin colonization by MRSA. J Clin Microbiol. 47:3769–3772. 2009.PubMed/NCBI

19 

Sarikonda KV, Micek ST, Doherty JA, Reichley RM, Warren D and Koller MH: Methicillin-resistant Staphylococcus aureus nasal colonization is a poor predictor of intensive care unit-acquired of methicillin-resistant Staphylococcus aureus infections requiring antibiotic treatment. Crit Care Med. 38:1991–1995. 2010.

20 

Holfelder M, Eigner U, Turnwald AM, Witte W, Weizenegger M and Fahr A: Direct detection of Staphylococcus aureus in clinical specimens by a nucleic acid-based hybridization assay. Clin Microbiol Infect. 12:1163–1167. 2006.

21 

Paule SM, Pasquariello AC, Hacek DM, et al: Direct detection of Staphylococcus aureus from adult and neonate nasal swab specimens using real-time polymerase chain reaction. J Mol Diagn. 6:191–196. 2004.

Related Articles

Journal Cover

January 2013
Volume 7 Issue 1

Print ISSN: 1791-2997
Online ISSN:1791-3004

Sign up for eToc alerts

Recommend to Library

Copy and paste a formatted citation
x
Spandidos Publications style
Oh A, Lee JK, Lee HN, Hong YJ, Chang YH, Hong S and Kim DH: Clinical utility of the Xpert MRSA assay for early detection of methicillin-resistant Staphylococcus aureus. Mol Med Rep 7: 11-15, 2013
APA
Oh, A., Lee, J.K., Lee, H.N., Hong, Y.J., Chang, Y.H., Hong, S., & Kim, D.H. (2013). Clinical utility of the Xpert MRSA assay for early detection of methicillin-resistant Staphylococcus aureus. Molecular Medicine Reports, 7, 11-15. https://doi.org/10.3892/mmr.2012.1121
MLA
Oh, A., Lee, J. K., Lee, H. N., Hong, Y. J., Chang, Y. H., Hong, S., Kim, D. H."Clinical utility of the Xpert MRSA assay for early detection of methicillin-resistant Staphylococcus aureus". Molecular Medicine Reports 7.1 (2013): 11-15.
Chicago
Oh, A., Lee, J. K., Lee, H. N., Hong, Y. J., Chang, Y. H., Hong, S., Kim, D. H."Clinical utility of the Xpert MRSA assay for early detection of methicillin-resistant Staphylococcus aureus". Molecular Medicine Reports 7, no. 1 (2013): 11-15. https://doi.org/10.3892/mmr.2012.1121